AC
: Automatically calculate the water supply.
·
Err
: Run overtime, check make-up water
source and pump / solenoid valve
·
Ove
: the number of times exceeds the limit,
check that the outlet pipe cannot be lower
than the water surface
1
2
·
Pau
: The system is paused. Press the Set
button to release the pause.
·
ERP
: The circuit is abnormal. Please replace
the water pump or solenoid valve.
·
SHiG
: The water level is too high for more
than 20 minutes.
Hardware
related
A.T.O.Related
3
4
Done: automatic calibration is complete.
·
Star
: Water is being poured into the container
·
Hig
: The water level is too high when starting
the water change. Please lower the water level.
·
Oro: Drain timeout, please check the drain
pump
· Iro: water inlet timeout, please check the
water inlet device
5
·
Aro: simultaneous water inlet and outlet
timeout, please check the water inlet and
outlet device.
If there are no hardware issues, try
running the device calibration again.
Timeout related
4
5
·
The alarm will be automatically cancelled
when the water level returns to normal.
·
The buzzer alarm will be triggered when the
water level reaches the HIGH level.
·
In order to prevent false alarms due to the need
to stop the pump for feeding, the buzzer alarm
will only be triggered if the water level is too high
for more than 20 minutes.
Level
monitoring
Level
monitoring
Show code meaning
A.W.C.Related
Timeout related
17 18