Smart Power Systems
®
A. C. MODULAR GENERATOR SYSTEM
Page 22 of 52
Figure 9
– 120VAC Alternate Wiring
WARNING:
Wiring of the A.C. modular generator system and electrical distribution throughout
the vehicle must be done in accordance with applicable sections in the National Fire
Protection
Association’s document NFPA 1901, the National Electrical Code
®
and/or
other applicable, recognized electrical code and by a certified electrician.
Smart Power Systems
®
A.C. modular generators are supplied with the neutral
bonded to ground. Refer to Nat
ional Fire Protection Association’s document NFPA
1901, National Electrical Code
, and/or other applicable recognized electrical codes
before wiring an SPS A.C. modular generator system.
Never wire any loads to the generator’s output without a circuit breaker in series
with the load. Damage to the generator, to the components within that circuit,
electrical shock, or fire may result if a short occurs in an unprotected circuit. Run
all 120 VAC and 240 VAC electrical connections between the generator and the
distribution panel in conduit. Bypassing the SPS factory installed breaker will void
the system’s warranty. Replacement breakers must be obtained from Smart Power
Systems
®
approved sources only.
Do not perform any wiring installations or modifications while the system is
operating. The A.C. modular generator system will generate enough voltage to
produce a fatal shock.
Never touch any live connections while the system is operating.
Never operate the system with the generator cover removed.