Where the smart things are
®
sm
2015 Compacta International, Ltd. - Rev.
8/2015
ZBMLC30
and Smartenit are trademarks of Compacta International, Ltd.
ZigBee is a registered trademark of the ZigBee Alliance
(949) 429-3303
Technical Support
Smartenit.com
Quick Start Guide -
ZBMLC30
Model #4040B
Product Brief
Installation
Local Control & LED Indicators
Wireless Triple-Relay Metering Load Controller
The ZBMLC30 interfaces wirelessly with ZigBee Pro controllers and
gateways in the Home Automation (HA) profile. This high power
load controller is ideal for applications that require control and
monitoring of loads up to 240VAC at 30Amps.
The device measures the energy delivered to the load in Kilo-
watt-Hours, enabling the intelligent management of large applianc-
es to maximize energy conservation. Two-speed appliances such
as pool pump motors are handled directly with an integrated third
relay.
Line 2 Out
Line 1 In
Load 1 Out
Load 2 Out
Line 2 In
The ZBMLC30 can be mounted indoors or outdoors
Mounting
Can be mounted with #6 screws through mounting holes from the inside or
with optional Mounting tabs (sold separately).
For water tight operation,
all four mounting holes must be used or otherwise sealed.
Mounting Tabs
(sold separately)
Wire Connections
LOAD LED
STATUS LED
SET
Pushbutton
SET Pushbutton - used to factory reset device, join
network, bind to other devices, and for local control. A
single tap cycles loads from OFF, to Load 2 ON (Red LED),
to Load 1 ON (Green LED) with each successive tap.
Load LED - Indicates when load is energized (Green if high
power, Red if low power. Green/Red flashing, both loads
on)
Status LED - Indicates network join and bind status.
** High voltage installations should always be performed by a licensed professional **
Wire Color
Make Connection To
Black
Electrical service Line1 (Hot for 120VAC or L1 for 240VAC)
Brown
Electrical service Line2 (Neutral for 120VAC or L2 for 240VAC)
Red
L1 to Load 1 (High Speed if 2-speed appliance)
Yellow
L1 to Load 2 (Low speed if 2-speed appliance)
Blue
L2 to Load (Common to Load 1 and Load 2)
Mounting Holes
A water tight
connector
and conduit
must be used
for outdoor
installation