background image

Where the smart things are

®

sm

2015 Compacta International, Ltd. - Rev. 

8/2015

ZBMLC30

 

and Smartenit are trademarks of Compacta International, Ltd.

ZigBee is a registered trademark of the ZigBee Alliance

(949) 429-3303

Technical Support

Smartenit.com

Quick Start Guide - 

ZBMLC30  

Model #4040B

Product Brief

Installation

Local Control & LED Indicators

Wireless Triple-Relay Metering Load Controller

The ZBMLC30 interfaces wirelessly with ZigBee Pro controllers and 

gateways in the Home Automation (HA) profile.  This high power 

load controller is ideal for applications that require control and 

monitoring of loads up to 240VAC at 30Amps.
The device measures the energy delivered to the load in Kilo-

watt-Hours, enabling the intelligent management of large applianc-

es to maximize energy conservation.  Two-speed appliances such 

as pool pump motors are handled directly with an integrated third 

relay.

Line 2 Out 

Line 1 In

Load 1 Out 

Load 2 Out 

Line 2 In

The ZBMLC30 can be mounted indoors or outdoors

Mounting

Can be mounted with #6 screws through mounting holes from the inside or 

with optional Mounting tabs (sold separately). 

For water tight operation, 

all four mounting holes must be used or otherwise sealed.

Mounting Tabs 

(sold separately)

Wire Connections

LOAD LED

STATUS LED

SET 

Pushbutton

SET Pushbutton - used to factory reset device, join 

network, bind to other devices, and for local control. A 

single tap cycles loads from OFF, to Load 2 ON (Red LED), 

to Load 1 ON (Green LED) with each successive tap.
Load LED - Indicates when load is energized (Green if high 

power, Red if low power. Green/Red flashing, both loads 

on)
Status LED - Indicates network join and bind status.

** High voltage installations should always be performed by a licensed professional **

Wire Color

Make Connection To

Black

Electrical service Line1 (Hot for 120VAC or L1 for 240VAC)

Brown

Electrical service Line2 (Neutral for 120VAC or L2 for 240VAC)

Red

L1 to Load 1 (High Speed if 2-speed appliance)

Yellow

L1 to Load 2 (Low speed if 2-speed appliance)

Blue

L2 to Load (Common to Load 1 and Load 2)

Mounting Holes

A water tight 

connector 

and conduit 

must be used 

for outdoor 

installation 