MyOT interface/actuator for OpenTherm Boilers 

User manual and data sheet

 

 

10 

 

Parameter 

number (dec) 

Parameter 

Bytes 

Mode (Read/ 

Write) 

Sign 

90 

ID LSB 

No 

91 

Version 

No 

94 

ID HSB 

No 

95 

Report rate (minutes, 0: continuous) 

No 

Max setpoint of the boiler

 

No 

Min boiler setpoint

 

No 

Setpoint Max DHW

 

No 

Setpoint Min DHW

 

No 

30 

Summer mode (0: no 1: yes)

 

L/S

 

No 

31 

Enabling DHW (0: no 1: yes) 

L/S

 

No 

10 

Error flag if present (0 otherwise)

 

No 

11 

Error code if present (0 otherwise)

 

No 

 

COMMAND_CLASS_SECURITY 

MyOT device supports unauthenticated S0 and S2 security. 

Warranty and customer support

 

Visit our website at the link:

http://www.ecodhome.com/acquista/garanzia-eriparazioni.html

 

 

 

 

If you encounter technical problems or malfunctions, visit the site: 

http://helpdesk.smartdhome.com/users/register.aspx

  

 

 

 

After a short registration you can open a ticket online, also attaching images. One of our technicians will answer you as 

soon as possible. 

 

 

Содержание 01335-2080-00

Страница 1: ...actuator for OpenTherm boilers the latest generation device that allows you to monitor the performance of the OpenTherm boilers on which it is installed Z Wave certified it is compatible with any gat...

Страница 2: ...eep out of reach of children 9 Do not carry out any maintenance on the device but always contact the assistance network 10 Contact the service network if one or more of the following conditions occur...

Страница 3: ...www myvirtuosohome com the documentation will always be updated Intended use This device has been designed for the monitoring of OpenTherm boiler Should it be improperly used and or modifications not...

Страница 4: ...anual and data sheet 4 The parts of the MyOT interface actuator for OpenTherm boilers Figure 1 Buttons and LEDs Functions Button see Wi Fi configuration and Z Wave configuration sections Reset Button...

Страница 5: ...o polarization 2 Pay close attention to the 5V power supply connection respecting the and as in table 1 Warning LEDs The IoB device has two signaling LEDs one green and one red The green LED signals t...

Страница 6: ...chase a paid package of the IoB portal Please contact the sales representative or the company by sending an email to info smartdhome com WI FI Configuration using application recommended For correct d...

Страница 7: ...h will be caused by an incorrectly performed installation or by a failure caused by the customer will be quoted and will be charged to those who purchased the system If you have good experience with t...

Страница 8: ...e MyOT device by pressing the function button for 8 seconds Data Mapping MyOT device supports the following command class COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_BAS...

Страница 9: ...le the unit of each measurement is correctly communicated in the command class report message Mode dec Measure 1 Heating setpoint 13 DHW setpoint COMMAND_CLASS_SENSOR_MULTILEVEL This CC provides a ser...

Страница 10: ...No 31 Enabling DHW 0 no 1 yes 1 L S No 10 Error flag if present 0 otherwise 2 L No 11 Error code if present 0 otherwise 2 L No COMMAND_CLASS_SECURITY MyOT device supports unauthenticated S0 and S2 se...

Страница 11: ...MyOT interface actuator for OpenTherm Boilers User manual and data sheet 11 SmartDHOME Srl V le Longarone 35 20080 Zibido San Giacomo MI info smartdhome com Product Code 01335 2080 00 Rev 06 2021...

Отзывы: