MyOT interface/actuator for OpenTherm Boilers
User manual and data sheet
9
COMMAND_CLASS_THERMOSTAT_SETPOINT
This CC can be used to manage the boiler setpoints.
N.B.
The maximum and minimum value of the setpoints are displayed with the COMMAND_CLASS_CONFIGURATION.
This was done to support a non-exclusion/inclusion boiler hot swap. It is also important to know that setting the heating
setpoint to 0 is equivalent to setting it to the maximum reported by the boiler. Otherwise, setting the DHW setpoint to 0 is
equivalent to setting it to 40 ° C. The map between the 'mode' and the setpoint is as follows, while the unit of each
measurement is correctly communicated in the command class report message.
Mode (dec)
Measure
1
Heating setpoint
13
DHW setpoint
COMMAND_CLASS_SENSOR_MULTILEVEL
This CC provides a series of measurements which are obtained from the boiler.
Below is the mapping between the "sensor type" and the "supplied measurement". The unit of each measure is
communicated as specified in the CC report message.
Sensor type (dec)
Measure
9
Heating circuit pressure
19
Total DHW
23
Return water temperature
56
DHW Flow
61
Boiler heating modulation
62
Boiler water temperature
63
DHW Temperature
65
Exhaust fumes temperature
COMMAND_CLASS_CONFIGURATION
This CC provides a series of measurements which are obtained from the boiler.
Below is the mapping between the “Parameter number” and the supplied “Parameter”.