Controls of charging cable version one
:
Voltage indicator lamp
;
Charging process indicator lamp
=
Indicator lamp temperature monitor
?
Electrical fuse and control system indi-
cator lamp
The indicator lamps on the charging cable
indicate the following:
Indicator lamp
:
Lights up
white
Voltage is switched on. The
high-voltage battery can
be charged.
Indicator lamp
;
Flashes
green
High-voltage battery is
charging.
Indicator lamp
=
Lights up
red
With flashing green indica-
tor lamp
;
: the charge out-
put is reduced due to over-
temperature.
Without flashing green
indicator lamp
;
: charg-
ing was terminated due to
overtemperature on the
charging cable.
Flashes red
Charging was terminated
due to overtemperature on
the mains socket.
Indicator lamp
?
Flashes red
quickly
An internal malfunction
has occurred. The high-
voltage battery cannot be
charged.
The infrastructure has a
malfunction. The high-
voltage battery cannot be
charged.
If the control element detects a fault current
or a malfunction, the charging process is
interrupted. The charging process will be
resumed automatically when the malfunc-
tion has been rectified.
Controls of charging cable version two
:
Indicator lamp for charge current setting
;
Voltage indicator lamp
=
Charging process indicator lamp
?
Electrical fuse and control system indi-
cator lamp
A
Button for setting the charge current
The indicator lamps on the charging cable
indicate the following:
Indicator lamp
:
Lights up
green
Value is set as the desired
charging current.
Flashes
orange
Depending on the mains
socket, the value cannot be
set as the desired charging
current.
Charging the high-voltage battery
83
>> Driving
.
Z