Programming Light 

Indicates when the Central Monitor is in programming mode. If the 

light is on, the Central Monitor is in programming mode; if the light is 

off, it is not in programming mode. 

1.  Press once to exit programming mode.

2.  Press once to silence the Central Monitor

 

and

 

erase/clear call memory.

Extend the antenna fully to ensure the best possible reception and range 

between the Central Monitor and any programmed Nurse Call buttons or 

other components or to optimize the range between the Central Monitor 

and pagers.

1.  Slide the base off of the Central 

Monitor

2.   Screw base into wall so 

that hooks face out

3.   Slide the Central Monitor onto the base (now 

screwed onto the wall) so that the hooks from 

the Central Monitor connect to the hooks on 

the base.

Programming 
Light

Reset
Button

Antenna

Screw Holes

Hooks

Hooks

Base

Reset Button

Antenna

Wall Mounting the 433-CMU

To program Nurse Call Buttons or other components into a new or empty system:

1.  Refer to previous pages for instructions specific to each component.

To erase all Nurse Call Buttons and other components currently programmed into the Central Monitor System:

1.  Press and hold “Record/Add” Button until you hear 2 dings and a melodic tone. 

2.  Press “Reset” button to exit programming mode.

WARNING:

 Pressing the “Record/Add” button will erase/clear all programming from the Central Monitor. After pressing the “Record/Add” 

button, all Nurse Call Buttons or other components that were programmed into the Central Monitor will no longer be recognized by the 
Central Monitor until they are reprogrammed. Numbers will flash across the Central Monitor to indicate that no Nurse Call Buttons or other 
components are currently programmed to work with the Central Monitor.

WARNING: 

Pressing the “Reset” button will erase/clear the Central Monitor’s 

memory of call history so that the “Call Review” button will be unable to recall any 

calls made prior to pressing the “Reset” button.

433-CMU

433-CMU

433-CMU Back

433-CMU Back

433-CMU 

Back

9

Record/Add Button 

Use this button when you wish to

1.  Program Nurse Call Buttons or other components into a new or 

empty Central Monitor system

2.  Erase all Nurse Call Buttons and other components currently 

programmed into the Central Monitor system

Record/Add

WARNING:

 If you do not wait for the Central Monitor to make a melodic tone before pressing the next Nurse Call Button or other component, 

each component will be programmed to the same number on the Central Monitor. In this situation, the Central Monitor will speak one 

number for the component, but show a different number to represent the room. When multiple components are programmed to the same 

number on the Central Monitor, 

THE NUMBER SPOKEN WILL NOT CORRESPOND WITH THE NUMBER DISPLAYED

. This may be useful when 

multiple devices are being used in the same room, but not for any other situation.

WIRELESS CALL SYSTEM

CALL REVIEW

VOLUME

LANGUAGE

REPLACE/ADD

RECORD/ADD

RESET

1   2   3   4   5   6   7   8   9   10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30 

Содержание 433-CMU

Страница 1: ...23 12V 433 PGD Caegiver Pocket Pager with LCD Display 433 PG Caegiver Pocket Pager 433 NC Wireless Nurse Call Button Optional Accessories WIRELESS CALL SYSTEM CALL REVIEW VOLUME LANGUAGE REPLACE ADD R...

Страница 2: ...2 This page intentionally left blank...

Страница 3: ...lay optional 433 NCNurseCallButton optional _ A23 12V _ A23 12V Front Top Inside Insert a flathead screwdriver into notch and gently twist until the button pops open Gently pry open using tab at top o...

Страница 4: ...ase the next Nurse Call Button or other component that you would like to program repeating step b until all buttons components have been programmed Call Alarm Unlock Lock Pager VOL LANGUAGE REVIEW Pag...

Страница 5: ...sired the Fall Alarm Monitor TL 2100 series Plug the sensor pad floor mat or seat belt into phone style port at bottom of desired Fall Alarm Monitor TL 2100 series Press sensor pad step on floor mat o...

Страница 6: ...RESPOND WITH THE NUMBER DISPLAYED This may be useful when multiple devices are being used in the same room but not for any other situation 433 CMU 433 CMU 433 CMU 433 CMU 433 CMU 433 CMU a b a e c c C...

Страница 7: ...Call Review and Reset features refer to pages 7 and 8 of these instructions ON OFF VOL LANGUAGE REVIEW Pager VOL LANGUAGE REVIEW up to 300 feet IMPORTANT The end user is responsible for testing syste...

Страница 8: ...r component 1 Press and hold Replace Add Button until you hear 2 dings and a melodic tone 2 Repeatedly press the Call Review Button to scroll through the numbers on the Central Monitor until you get t...

Страница 9: ...ramming mode WARNING Pressing the Record Add button will erase clear all programming from the Central Monitor After pressing the Record Add button all Nurse Call Buttons or other components that were...

Страница 10: ...you remove batteries when the Central Monitor is not in use When batteries are replaced all Nurse Call Buttons and other components that were programmed to work with the Central Monitor prior to remo...

Страница 11: ...This page intentionally left blank...

Страница 12: ...implied warranties Except for this limited warranty NO EXPRESS OR IMPLIED WARRANTIES ARE GIVEN AND NO AFFIRMATION OF SELLER BY WORDS OR ACTION WILL CONSTITUTE A WARRANTY THE GOODS BEING PURCHASED ARE...

Отзывы: