WIRELESS CALL SYSTEM
CALL REVIEW
VOLUME
LANGUAGE
REPLACE/ADD
RECORD/ADD
RESET
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
WIRELESS CALL SYSTEM
CALL REVIEW
VOLUME
LANGUAGE
REPLACE/ADD
RECORD/ADD
RESET
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
WIRELESS CALL SYSTEM
CALL REVIEW
VOLUME
LANGUAGE
REPLACE/ADD
RECORD/ADD
RESET
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
WIRELESS CALL SYSTEM
CALL REVIEW
VOLUME
LANGUAGE
REPLACE/ADD
RECORD/ADD
RESET
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
WIRELESS CALL SYSTEM
CALL REVIEW
VOLUME
LANGUAGE
REPLACE/ADD
RECORD/ADD
RESET
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
WIRELESS CALL SYSTEM
CALL REVIEW
VOLUME
LANGUAGE
REPLACE/ADD
RECORD/ADD
RESET
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
WARNING:
If you do not wait for the Central Monitor to make a melodic tone before pressing the next Nurse Call Button or other
component, each component will be programmed to the same number on the Central Monitor. In this situation, the Central Monitor will
speak one number for the component, but show a different number to represent the room. When multiple components are programmed to
the same number on the Central Monitor,
THE NUMBER SPOKEN WILL NOT CORRESPOND WITH THE NUMBER DISPLAYED
. This may be
useful when multiple devices are being used in the same room, but not for any other situation.
433-CMU
433-CMU
433-CMU
433-CMU
433-CMU
433-CMU
a
b
a
e
c
c
CordLess® Transmitter (
TM-03
) (optional) Programming Instructions
Press on the sensor pad or step on floor
mat. The Central Monitor will speak and
display a number. The number shown is the
Cordless Transmitter’s identification number
on the Central Monitor.
Plug a CordLess® Transmitter into a CordLess®
Sensor Pad or Floor Mat. Repeat this step for
every CordLess Pad and Transmitter
you plan to use with the Central
Monitor system.
Press and hold “Record/
Add” button until you
hear 2 dings and a
melodic tone.
Press and hold “Record/
Add” button until you hear
2 dings and a melodic
tone.
Wait for the Central Monitor
to make a melodic tone. Then,
repeat steps “c” & “d” with the
next Monitor Adaptor or follow
programming directions for
another component that you
would like to program.
Wait for the Central Monitor to
make a melodic tone. Then, repeat
step “c” with the next Exit Alarm
or follow programming directions
for another component that you
would like to program.
Turn on the transmitter. The
ON/OFF switch located on the
side of the Transmitter.
Sensor
Pad
d
TM-03
CordLess®
Transmitter
ON/OFF Switch
b
433-EXT Door/Window Exit Alarm (optional) Programming Instructions
Touch the two parts of the Exit
Alarm together and then the Central
Monitor will display and speak the
number the Exit Alarm has been
programmed to.
f
d
Press the “Reset” button to
exit programming mode.
Press the “Reset” button to
exit programming mode.
433-EXT
TM-03
TM-02
6