SMART 433-CMU Скачать руководство пользователя страница 10

•  Call

: When switched 

to this setting, the 

Central Monitor will 

alert the caregiver 

by voicing the 

programmed number 

of the activated 

device.

•  Alarm:

 Call (above) 

is preceded by a siren 

sound.

•  Unlock

 when 

programming

•  Lock

 to prevent 

tampering or loss 

of  programming.

To plug the Central 

Monitor into a wall outlet, 

use a Smart AC-04 9-Volt 

AC adaptor.

An external speaker can 

be plugged into this 

outlet if you wish for 

louder volume.

Call/Alarm

Unlock/Lock

DC Input

Speaker

Call/Alarm Switch

Unlock/Lock Switch

DC Input

External Speaker Outlet

Call

Alarm

Unlock

Lock

Call

Alarm

Unlock

Lock

Call

Alarm

Unlock

Lock

Call

Alarm

Unlock

Lock

Notes

•  Low power affects performance.  

Symbol indicates that battery is low. Replace batteries 

when this symbol appears on the Central Monitor. 

•  There is no ON/OFF switch for the Central Monitor. If you choose not to use the AC-04 AC adaptor 

to power the Central  Monitor and depend on batteries, it is recommended that you remove 
batteries when the Central Monitor is not in use. When batteries are replaced, all Nurse Call 
Buttons and other components that were programmed to work with the Central Monitor prior 
to removing the batteries will still be programmed to work when the batteries are replaced. They 
will not have to be re-programmed.

•  Avoid outside interference. When in programming mode, be sure that no Nurse Call Button or 

other component that you are not currently programming is active within range of the Central 
Monitor (for example: do not press the Nurse Call Button, do not separate Exit Alarm).  The        
symbol indicates that a component is active within range of the Central Monitor.

•  To ensure optimal wireless performance and reduce electrical interference, do not place the 

Central Monitor close to metal objects or other electronic devices. 

•  Do not expose the Central Monitor to heat or direct sunlight.
•  Avoid dampness and water.
•  Numbers flashing across the screen of the Central Monitor indicates that there are no Nurse Call 

Buttons or other components currently programmed to work with the Central Monitor.

433-CMU

433-CMU

433-CMU

433-CMU

10

Содержание 433-CMU

Страница 1: ...23 12V 433 PGD Caegiver Pocket Pager with LCD Display 433 PG Caegiver Pocket Pager 433 NC Wireless Nurse Call Button Optional Accessories WIRELESS CALL SYSTEM CALL REVIEW VOLUME LANGUAGE REPLACE ADD R...

Страница 2: ...2 This page intentionally left blank...

Страница 3: ...lay optional 433 NCNurseCallButton optional _ A23 12V _ A23 12V Front Top Inside Insert a flathead screwdriver into notch and gently twist until the button pops open Gently pry open using tab at top o...

Страница 4: ...ase the next Nurse Call Button or other component that you would like to program repeating step b until all buttons components have been programmed Call Alarm Unlock Lock Pager VOL LANGUAGE REVIEW Pag...

Страница 5: ...sired the Fall Alarm Monitor TL 2100 series Plug the sensor pad floor mat or seat belt into phone style port at bottom of desired Fall Alarm Monitor TL 2100 series Press sensor pad step on floor mat o...

Страница 6: ...RESPOND WITH THE NUMBER DISPLAYED This may be useful when multiple devices are being used in the same room but not for any other situation 433 CMU 433 CMU 433 CMU 433 CMU 433 CMU 433 CMU a b a e c c C...

Страница 7: ...Call Review and Reset features refer to pages 7 and 8 of these instructions ON OFF VOL LANGUAGE REVIEW Pager VOL LANGUAGE REVIEW up to 300 feet IMPORTANT The end user is responsible for testing syste...

Страница 8: ...r component 1 Press and hold Replace Add Button until you hear 2 dings and a melodic tone 2 Repeatedly press the Call Review Button to scroll through the numbers on the Central Monitor until you get t...

Страница 9: ...ramming mode WARNING Pressing the Record Add button will erase clear all programming from the Central Monitor After pressing the Record Add button all Nurse Call Buttons or other components that were...

Страница 10: ...you remove batteries when the Central Monitor is not in use When batteries are replaced all Nurse Call Buttons and other components that were programmed to work with the Central Monitor prior to remo...

Страница 11: ...This page intentionally left blank...

Страница 12: ...implied warranties Except for this limited warranty NO EXPRESS OR IMPLIED WARRANTIES ARE GIVEN AND NO AFFIRMATION OF SELLER BY WORDS OR ACTION WILL CONSTITUTE A WARRANTY THE GOODS BEING PURCHASED ARE...

Отзывы: