Program Components to Work with Central Monitor
2
Adjust Language and Volume on Central Monitor and Pager
433-NC Nurse Call Button (optional) Programming Instructions
Adjust volume by pressing
“Volume” buttons on Central
Monitor and/or optional pager.
Choose from 3 volume options
by repeatedly pressing “Volume
Button” until you find desired
volume. Monitor is shipped
with alarm volume set at 90
decibels (90 decibels is the
legally accepted occupational
noise allowance).
Press and release the Nurse Call
Button. The Central Monitor will
speak and display a number.
Number shown is the Nurse Call
Button’s identification number
on the Central Monitor. Wait for a
melodic tone before programming
additional buttons/components
or exiting.
Before programming the Central
Monitor and components, make sure
the switch on the side of the Central
Monitor is set to “Unlock.” When all
programming is complete, prevent
tampering by setting this switch to
“Lock.”
Press and release the next Nurse
Call Button or other component
that you would like to program,
repeating step
b
until all
buttons/components have been
programmed.
Call
Alarm
Unlock
Lock
Pager
VOL
LANGUAGE
REVIEW
Pager
VOL
LANGUAGE
REVIEW
To adjust language or
select a song, press the
“Language” buttons
on the Central Monitor
and/or optional pager
(ON/OFF switch on side
of pager must first be
switched to “ON” or ).
Press “Language” button
repeatedly to scroll
through the available
options. When you find
your desired selection,
stop pressing the button.
433-PG
433-PG
Before programming the Central Monitor
and components, be sure to read through
directions for all of the components you will be
programming to work with your Central Monitor.
Make sure you are prepared to program all of
the components before you begin.
The Central
Monitor automatically exits programming mode
after 30 seconds of inactivity. If you are not
prepared with all of your components, you may
be forced to start again at the beginning.
433-NC
433-NC
+
_
A23-12V
+
_
A23-12V
WARNING:
If you do not wait for the Central Monitor to make a melodic tone before pressing the next Nurse Call Button or other
component, each component will be programmed to the same number on the Central Monitor. In this situation, the Central Monitor will
speak one number for the component, but show a different number to represent the room. When multiple components are programmed to
the same number on the Central Monitor,
THE NUMBER SPOKEN WILL NOT CORRESPOND WITH THE NUMBER DISPLAYED
. This may be
useful when multiple devices are being used in the same room, but not for any other situation.
433-CMU
d
Press the “Reset” button to
exit programming mode
when programming is
complete.
a
c
Press and hold the
“Record/Add” button
until you hear 2 dings
and a melodic tone.
433-CMU