![Smart Storm Greasebuster Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/smart-storm/greasebuster/greasebuster_instruction-information_1296160010.webp)
8.0
ELECTRICAL INSTALLATION
Important:
Before wiring up the control panel check all wiring is secure in existing terminals as shipping might
have caused terminals to loosen.
Installation should only be carried out by a qualified engineer.
The Geasebuster has been preprogramed for optimum speed and heater temperature. However,
industrials waste varies in density, solid content and temperature. The user may wish to change the
setting to obtain best performance.
Electrical Wiring Protocol
L1-U
L2-V
L3-W
L1- Live
L2-Neutral
8.1
ELECTRICAL AND INSTRUMENT COMPONENTS
ELECTRICAL
Mains Isolator
Emergency Stop
Fuse holder (10A)
Thermistor (K Type)
Heater Plate (200W, 230VAC)
Mains Cable
Thermistor cable 5m
Heater Cable 5m
MCB for Temperature Controller (6A)
MCB for Inverter Drive (6A)
230VAC Single Phase motor (<1A)
INSTRUMENTS
Temperature Controller (230VAC, 1A)
Inverter Speed Controller (230VAC, 3.6A)
Содержание Greasebuster