APPENDIX B
REMOTELY MANAGING THE SYSTEM THROUGH AN RS-232 SERIAL INTERFACE
83
smarttech.com/kb/170910
Service Information
These commands are used in servicing and manufacturing the projector. They are hidden from the
user during normal operation.
Command/response definitions
Command
Response
Powered off
get displayhour
displayhour=[current]
no
set testpattern [target]
testpattern=[current]
no
set colorwheelidx
[target]
colorwheelidx=
[current]
no
get colorwheelidx
colorwheelidx=
[current]
no
get failurelog
failurelog=[current]
yes
get error#
error#=[current]
yes
set factoryreset
[target]
factoryreset=[current]
yes
set highspeedfan
[target]
highspeedfan=
[current]
no
get highspeedfan
highspeedfan=
[current]
no
set statereporting
[target]
statereporting=
[current]
yes
get statereporting
statereporting=
[current]
yes
get poweroverride
poweroverride=
[current]
no
set poweroverride
[target]
poweroverride=
[current]
no
Field definitions
Field
Possible Values
Description
current displayhour
0 to 20000
Current display hours.
target testpattern
= 1 to 4
Set the test pattern to pattern number (1 to 4). If
there’s only one test pattern, call it test
pattern 1.
Содержание M600ix3
Страница 16: ......
Страница 34: ......
Страница 41: ...CHAPTER4 MAINTAINING THE INTERACTIVE WHITEBOARD SYSTEM 33 smarttech com kb 170910 7 Remove the lamp module...
Страница 58: ......
Страница 68: ......
Страница 104: ......
Страница 106: ......
Страница 108: ......
Страница 112: ......
Страница 113: ......
Страница 114: ...SMART TECHNOLOGIES smarttech com support smarttech com contactsupport smarttech com kb 170910...