LD301 – Operation and Maintenance Instruction Manual
4.8
CONFIGURATION BRANCH (CONF)
Z:
Moves to the TOTAL branch.
S:
Enters the CONFIGURATION branch, starting with function display (LCD_1).
Display 1 (LCD_1)
Z:
Moves to the function Display 2 (LCD_2).
S:
Starts selection of variable to be indicated as primary display.
After activating (
S
), you can move around the options available in the following table by
activating (
Z
).
The desired variable is activated using (
S
). Escape leaves primary variable unchanged.
Display 2 (LCD_2)
Z:
Moves to the RANGE function.
S:
Starts selection of variable to be indicated as secondary display.
The procedure for selection is the same as for LCD_1, above.
DISPLAY LCD2/LCD1
DESCRIPTION
SP%
Setpoint (%)
PV%
Process Variable (%)
MV%
Output (%)
ER%
Error (%)
CO
Current - Output (mA)
TE
Sensor Temperature ( C)
SP
Setpoint (Eng. unit)
PV
Process Variable (eng. unit)
TO
Totalization
Nothing (only LCD-2)
ESC
-escape-
Table 4.3
- Display Indication
NOTA
In the transmitter mode, only the PV%, CO, TE, TO and PV may be displayed.
Besides, it is also possible to select option None for Display 2.
RANGE (RANGE)
Function Calibration (RANGE) presents the calibration options as a tree branch, as described on
Figure 4.6.
Fig. 4.6
– Local Range Tree
Содержание ld301
Страница 14: ...LD301 Operation and Maintenance Instruction Manual 1 8...
Страница 18: ...LD301 manual de Instru es Opera o e manuten o 2 4 Fig 2 3 LD301 Software Block Diagram...
Страница 50: ...LD301 Operation and Maintenance Instruction Manual 4 16...
Страница 55: ...Maintenance Procedure 5 5 Fig 5 1 Exploded View...
Страница 62: ...LD301 Operation and Maintenance Instruction Manual 5 12...
Страница 70: ...APPENDIX A...