Configuration
3.5
Relative
Index
Parameter Mnemonic
Object
Type
Data Type
Store
Size
Access
Parameter
usage/
Type of
transport
Default
value
Down-
load
Order
Mandatory /
Optional
(Class)
View
_1
22
SECONDARY_VALUE
_1_UNIT
Simple
Unsigned 16
N
2
r,w
C/a
mA
-
O (B)
23
SECONDARY_VALUE
_2
Record
DS-33
D
5
r
C/a
0
-
O (B)
24
SECONDARY_VALUE
_2_UNIT
Simple
Unsigned 16
N
2
r,w
C/a
%
-
O (B)
25
SCALE_IN
Array
Float
S
8
r,w
C/a
20.0
4.0
-
O(B)
26
SCALE_OUT
Array
Float
S
8
r,w
C/a
20.0
4.0
-
O(B)
27
MAX_SENSOR_VALU
E
Simple
Float
N
4
r,w
C/a
0.0
-
O (B)
28
MIN_SENSOR_VALUE
Simple
Float
N
4
r,w
C/a
0.0
-
O (B)
29
TERMINAL_NUMBER
Simple
Unsigned 8
S
1
r,w
C/a
0
-
O (B)
30
LIN_TYPE
Simple
Unsigned 8
S
1
r,w
C/a
0
-
O (B)
31
LOW_FLOW_CUT_OF
F
Simple
Float
S
4
r,w
C/a
0
-
O (B)
32
FLOW_LIN_SQRT_POI
NT
Simple
Float
S
4
r,w
C/a
0
O (B)
33-40
RESERVED
41
BACKUP_RESTORE
Simple
Unsigned 8
S
1
r,w
C/a
0
-
O (B)
42
XD_ERROR
Simple
Unsigned 8
D
1
r
C/a
0x10
-
O (B)
43
MAIN_BOARD_SN
Simple
Unsigned 32
S
4
r,w
C/a
0
-
O (B)
44
EEPROM_FLAG
Simple
Unsigned 8
D
1
r
C/a
FALSE
-
O (B)
45
FACTORY_GAIN_REF
ERENCE
Simple
Float
S
4
r,w
C/a
0
-
O (B)
46
ORDERING_CODE
Array
Unsigned 8
S
50
r,w
C/a
-
-
O (B)
Table 3.2 - Parameter Attribute
IF303 - CYCLIC CONFIGURATION
The PROFIBUS-DP and PROFIBUS-PA protocols have mechanisms against communication
failures between the slave device and the network master. For example, during initialization, these
mechanisms are used to check these possible errors. After powering up the field device (slave), it
can cyclically exchange information with the class 1 master, if the parameterization for the slave is
correct. This information is obtained using the GSD files (supplied by the device manufacturer, it
contains their descriptions). Through the commands below, the master executes all initialization
process with the PROFIBUS-PA device:
•
Get_Cfg: uploads the slave configuration on the master and checks network configuration;
•
Set_Prm: writes to the slave parameters and executes the parameterization network;
•
Set_Cfg: configures the slaves according to its outputs and inputs;
•
Get_Cfg: another command, where the master checks the slave configuration.
All these services are based on the information obtained from slave gsd files. The GSD file from
IF303 shows details such as, hardware and software revision, device bus timing and information
about cyclic data exchange.