Smalvic CU 36P OE/ISPH Скачать руководство пользователя страница 21

                                                                                         21                      9880023200-CU 36P NEUTRO 120312 

Natural gas supply line must have a natural service regulator. Inlet pressure 
to this appliance should be reduced to a maximum of 7 inches water column. 
Liquefied Petroleum L.P. / Propane gas supply line must have a L.P. gas 
pressure regulator. Inlet pressure to this appliance should be reduced to a 
maximum of 14 inches water column.  
Inlet pressure in excess of 14 in. W.C. can damage the appliance pressure 
regulator, or other gas components in this appliance and can result in a gas 
leak. 

 

a)  A manual gas valve must be put in an accessible location in the supply 

line ahead of the appliance, for turning on and turning off gas supply. If 
hob is to be connected to house piping with flexible or semi-rigid metal 
connectors for gas appliances, connector nuts must not be connected 
directly to pipe threads. The connectors must be installed with adapters 
provided with the connector. 

 

b)  The house piping and/or range connector used to connect the hob to the 

main gas supply must be clean, free of metal shavings rust, dirt and liquids 
(oil or water). Dirt, etc in the supply lines can work its way into the range 
manifold and in turn cause failure of the gas valves or controls and clog 
burners and/or pilot orifices. 

CAUTION:  DO NOT LIFT OR MOVE RANGE BY DOOR HANDLES OR 
BACKGUARD. 

 

c)  Turn off all pilots and main gas valve of other gas appliances. 

 

d)  Turn off main gas valve at meter. 

 

e)  Before connecting range apply pipe thread compound approved for LPG 

to all threads. 

 

f)  Connect range to gas supply at appliance pressure regulator using 

adapters supplied with flexible connector. Rigid pipe may also be used. 
See rating plate for type of gas range has been manufactured for. 

 

g)  Turn on main gas valve at meter, and relight pilots at other gas 

appliances. 

 

h)  Apply a non-corrosive leak detection fluid to all joints and fittings in the gas 

connection between the supply line shut-off valve and the range. Include 
gas fittings and joints in the range if connections were disturbed during 
installation. Check for leaks! Bubbles appearing around fittings and 
connections will indicate a leak. If a leak appears, turn off supply line gas 
shut-off valve, tighten connections, turn on the supply line gas shut off 
valve, and retest for leaks. 

Содержание CU 36P OE/ISPH

Страница 1: ...l The Installer must leave these instructions with the appliance and to the consumer to retain them for future reference WARNING If the information in this manual is not followed exactly a fire or exp...

Страница 2: ...nce from abnormal usage or by excessive loading of the oven door the appliance must be secured by a properly installed anti tip device To check if the device is installed properly remove lower storage...

Страница 3: ...ce unit gas burner The use of undersized utensils will expose flame out of the pot bottom to direct contact and may result in ignition of clothing Proper relationship of utensil to burner will also im...

Страница 4: ...umulate on hood and hood filter When a cooking hood is installed with appliance When flaming food under the hood turn the fan off The fan if operating may spread the flame When a cooking hood is insta...

Страница 5: ...ty device to warm up enough for a period of approx 5 seconds Then release the knob and verify the flame stays on Turn to desired temperature setting Attention When using the gas burner for the first t...

Страница 6: ...units are in seconds or minutes in the long time section The maximum time is 10h The format change will happen after 99 minutes and 50 seconds to 1 hour and 40 minutes To show time of day press butto...

Страница 7: ...CTRIC OVEN INSTRUCTION GUIDE FOR ELECTRIC OVEN CONTROL FEATURES MOD Oven Dual Fuel Range Note pre heat the oven for at least 10 minutes before putting food in ON AND OFF PILOT LIGHT B Whenever it is o...

Страница 8: ...ol will come on Any program which has been set is cancelled Semi Automatic Operation with cooking duration Select function and set required end time with the and button The A and cookpot symbols appea...

Страница 9: ...any time by selecting the appropriate function Setting Error Identification The setting is incorrect if time of day is in between the calculated cooking start and end times If an error has been made...

Страница 10: ...king This intensive heat is best for baking less tender meats CONVECTION BROIL Use this setting to combine the intense heat from the inner top element with the circulation assisted by the convection f...

Страница 11: ...upplying gas to the range COOKWARE To achieve optimum surface cooking performance select heavy gauge flat smooth bottom pans that conform to the diameter of the cooking area as well as straight sides...

Страница 12: ...o not touch the burner grates oven inner surface or surrounding areas until they have had sufficient time to cool Clean appliance with caution Use care to avoid steam burns if a wet sponge or cloth is...

Страница 13: ...L65S and VEFSGGL65S NOTES Control regularly the correct functioning of Top Surface gas valves oven gas thermostat and selector switch In case of abnormal functioning of these devices you must immediat...

Страница 14: ...do not attempt to open or close door or operate oven until door is properly replaced REPLACING THE OVEN LIGHT MOD Oven Gas Range Oven Dual Fuel Range WARNING To prevent electrical shock and or person...

Страница 15: ...o the installation of wall cabinets above the range and clearances to combustible wall above the cooking top see the installation drawing fig n 12 and 13 For Safety considerations do not install a ran...

Страница 16: ...second Model Number Plate is applied on the front page of the instruction booklet ANTI TIP DEVICE INSTALLATION INSTRUCTIONS MOD Oven Gas Range Oven Dual Fuel Range NOTE A risk of range tip over exist...

Страница 17: ...cket to the wall STEP 3 Range Installation A Align the range to its designated location and slide it back into position Make sure that the Anti Tip bracket plate is fully inserted into the range rear...

Страница 18: ...th the National Electrical Code ANSI NFPA 70 latest edition The three prong grounding plug offers protection against shock hazards DO NOT CUT OR REMOVE THE THIRD GROUNDING PRONG FROM THE POWER CORD PL...

Страница 19: ...supply wire neutral wire or N to position connect the Green ground electrical supply wire ground wire or E 2 For Double phase connection 120 208V 60 Hz for US fig 15B On position n 1 connect the Black...

Страница 20: ...in accordance with National Electrical Codes and suitable for the Range technical characteristics electrical ratings A 18 AWG three prong grounding plug flexible cord type SJT 3x18 AWG for the gas ove...

Страница 21: ...metal shavings rust dirt and liquids oil or water Dirt etc in the supply lines can work its way into the range manifold and in turn cause failure of the gas valves or controls and clog burners and or...

Страница 22: ...S CONVERSION MOD Oven Gas Range Oven Dual Fuel Range NOTE All gas adjustment must be done by a qualified service personnel only All Ranges are equipped with both Natural Gas and LP Gas injectors as we...

Страница 23: ...over and reinstall follow the NAT or LP indication figure 17A and 17B NOTE THE GAS TYPE YOU ARE CONVERTING TO MUST BE VISIBLE ON THE TOP OF THE INSTALLED APPLIANCE PRESSURE REGULATOR CAP SERVICE PART...

Страница 24: ...90 BROIL 13700 1 05 OVEN TECHNICAL DATA ELECTRICAL DATA Oven Gas Range CONVECTION GAS OVEN Oven Dual Fuel Range CONVECTION ELECTRIC OVEN VOLTAGE 120 Vac 60 Hz 120 240 208 Vac 60Hz TOTAL POWER 16000 B...

Страница 25: ...Oven Gas Range Oven Dual Fuel Range MOD Oven Gas Range Oven Dual Fuel Range Fig n 01 Fig n 02 MOD Oven Gas Range Fig n 03 MOD Oven Gas Range Fig n 04 MOD Oven Gas Range MOD Oven Dual Fuel Range MOD O...

Страница 26: ...26 9880023200 CU 36P NEUTRO 120312 Fig n 08 Fig n 09A Fig n 09B Fig n 10...

Страница 27: ...27 9880023200 CU 36P NEUTRO 120312 Fig n 11 Fig n 12...

Страница 28: ...28 9880023200 CU 36P NEUTRO 120312 Fig n 13 One bracket either location Fig n 14...

Страница 29: ...UTRO 120312 Fig 14A Fig n 15A Fig n 15B TERMINAL BLOCK CONNCTION FOR CANADA TERMINAL BLOCK CONNCTION FOR US 120 240V AC 60 Hz 120 208V AC 60 Hz MOD Oven Dual Fuel Range MOD Oven Dual Fuel Range MOD Ov...

Страница 30: ...30 9880023200 CU 36P NEUTRO 120312 Fig n 16 Fig n 18A MOD Oven Gas Range Oven Dual Fuel Range Fig n 17A Fig n 18B MOD Oven Gas Range Fig n 17B...

Страница 31: ...31 9880023200 CU 36P NEUTRO 120312 CONTROL PANEL FEATURES Fig n 19 Control Panel on range model Oven Dual Fuel Range Control Panel on range model Oven Gas Range...

Страница 32: ...ert slotted pin into the external cut as shown in the figure Third STEP 2 holding backguard in the upright position slide it forward till the vertical back lower flange is touching the back surface of...

Страница 33: ...33 9880023200 CU 36P NEUTRO 120312 WIRING DIAGRAM FOR RANGE WITH GAS OVEN MOD Oven Gas Range WIRING DIAGRAM FOR RANGE WITH ELECTRIC OVEN MOD Oven Dual Fuel Range...

Отзывы: