![Smalvic CU 36P OE/ISPH Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/smalvic/cu-36p-oe-isph/cu-36p-oe-isph_instruction-manual_1294769021.webp)
21 9880023200-CU 36P NEUTRO 120312
Natural gas supply line must have a natural service regulator. Inlet pressure
to this appliance should be reduced to a maximum of 7 inches water column.
Liquefied Petroleum L.P. / Propane gas supply line must have a L.P. gas
pressure regulator. Inlet pressure to this appliance should be reduced to a
maximum of 14 inches water column.
Inlet pressure in excess of 14 in. W.C. can damage the appliance pressure
regulator, or other gas components in this appliance and can result in a gas
leak.
a) A manual gas valve must be put in an accessible location in the supply
line ahead of the appliance, for turning on and turning off gas supply. If
hob is to be connected to house piping with flexible or semi-rigid metal
connectors for gas appliances, connector nuts must not be connected
directly to pipe threads. The connectors must be installed with adapters
provided with the connector.
b) The house piping and/or range connector used to connect the hob to the
main gas supply must be clean, free of metal shavings rust, dirt and liquids
(oil or water). Dirt, etc in the supply lines can work its way into the range
manifold and in turn cause failure of the gas valves or controls and clog
burners and/or pilot orifices.
CAUTION: DO NOT LIFT OR MOVE RANGE BY DOOR HANDLES OR
BACKGUARD.
c) Turn off all pilots and main gas valve of other gas appliances.
d) Turn off main gas valve at meter.
e) Before connecting range apply pipe thread compound approved for LPG
to all threads.
f) Connect range to gas supply at appliance pressure regulator using
adapters supplied with flexible connector. Rigid pipe may also be used.
See rating plate for type of gas range has been manufactured for.
g) Turn on main gas valve at meter, and relight pilots at other gas
appliances.
h) Apply a non-corrosive leak detection fluid to all joints and fittings in the gas
connection between the supply line shut-off valve and the range. Include
gas fittings and joints in the range if connections were disturbed during
installation. Check for leaks! Bubbles appearing around fittings and
connections will indicate a leak. If a leak appears, turn off supply line gas
shut-off valve, tighten connections, turn on the supply line gas shut off
valve, and retest for leaks.