CONNECTING THE RANGE
MOD: Oven Gas Range – Oven Dual Fuel Range
ELECTRICAL SUPPLY
The appliance, when installed, must be electrically grounded in accordance
with local codes or, in absence of local codes, with National Electrical Code,
ANSI/NFPA 70
In Canada the appliance must be installed in accordance with the current
CSA Standard C22.1 - Canadian Electrical Code part 1.
IMPORTANT:
The appliance must only be installed by a qualified and
specialized electrician.
ELECTRICAL INSTALLATION FOR RANGE WITH GAS OVEN
MOD: Oven Gas Range
This appliance is equipped with a three-prong grounding plug, which must be
plugged directly into a properly grounded three-hole single-phase 120 VAC
60 Hz 15 amps electrical outlet.
NOTE:
House wiring and fusing must comply with local codes. If no local
codes are applicable, wire in accordance with the National Electrical Code,
ANSI/NFPA 70 latest edition.
The three-prong grounding plug offers protection against shock hazards. DO
NOT CUT OR REMOVE THE THIRD GROUNDING PRONG FROM THE
POWER CORD PLUG.
If an ungrounded, two-hole or other type of electrical outlet is encountered, it
is the personal responsibility of the appliance owner to have the outlet
replaced with a properly grounded three-hole electrical outlet.
The cable cord connected to the appliance is a flexible type of cable. Pass it
through hole prepare in cabinet to plug it to wall socket.
To facilitate service, the flex cable must not be shortened and should be
routed to permit temporary removal of the appliance.
■
ELECTRICAL INSTALLATION FOR RANGE WITH ELECTRIC OVEN
MOD: Oven Dual Fuel Range
The Range can be installed either with a double-phase 120/240V ~ 60 Hz for
Canada and 120/208V ~ 60 Hz for US, use flexible cord type according with
National Codes. CAUTION: Be sure the electrical power is off from the
breaker box to the junction box until the range is installed and ready to
operate.