SMAC
LAC-26 Technical Reference Manual
4/29/2013 24
Command:
aTL -- Tell Integration Limit --
This command reports the integration limit value of the PID digital filter for servo axis 'a'.
Related Commands: TG, TI, TD
Command:
TMn
-- Tell Macros --
Argument:
-2 <= n <= 255
The Tell Macro (TM) command will display the commands which make up any macros that have
been defined. If 'n' >= 0 and 'n' <= 255, then the macro specified by 'n' be displayed. If 'n' = - 1, then all
the macros will be displayed preceded by the individual macro number. If 'n' =-2, then all macros will be
displayed and will be preceded by the letters "MD" and the individual macro number. This is useful when
downloading programs from the LAC-26 to a computer in that you need not re-enter the Macro Define
(MD) command and number at the beginning of each macro.
Related Commands: MD, RM
Command:
aTO -- Tell Optimal Position --
This command reports the desired position for servo axis 'a'. This value may be different from the
position reported by the TP command if the servo is moving or the controller is unable to drive the servo.
Related Commands: TT, TP
Command:
aTP - Tell Real Position --
This command reports the absolute position of servo axis 'a'. It may be used to monitor motion
during both the Motor On (MN) and the Motor Off (MF) states.
Related Commands: TT, TO
Command:
aTQ -- Tell Torque --
his command reports the current output torque being commanded for servo axis 'a'. This value
will be either that which is generated by the PID output or which is set by the user via the Torque Mode
(QM).
Command:
TRn -- Tell Contents of Register 'n' --
Argument:
0 <= n <= 511
This command reports the value contained by Register 'n'.
Related Commands: Register Commands