14 Technical Data
SMA Solar Technology AG
Operating manual
SBSxx-10-BE-en-11
135
SBS3.7-10
SBS5.0-10
SBS6.0-10
Surge category in ac-
cordance with
IEC 60664-1
III
III
III
* The charging and discharging voltage of the connected batteries must be in the range of 220 V and
500 V in order to make optimum use of the power of the inverter
** Warning! Danger of fire due to use of non-approved batteries. Only use batteries approved by SMA
Solar Technology AG (technical information with list of approved batteries at www.SMA-Solar.com)
AC output, secure power supply operation
Maximum AC power
3680 W
Nominal AC voltage
230 V
Maximum output current
16 A
Minimum load
1 W
Protective Devices
DC reverse polarity protection
Available
Input-side disconnection point
Not available
AC short-circuit current capability
Current control
Ground fault monitoring
Available
Grid monitoring
SMA Grid Guard 6
Maximum permissible fuse protection
50 A
All-pole sensitive residual-current monitoring unit
Available
General data
Width x height x depth
535 mm x 730 mm x 198 mm
Weight
26 kg
Length x width x height of the packaging
600 mm x 800 mm x 300 mm
Weight including packaging
30 kg
Climatic category in accordance with
IEC 60721-3-4
4K4H
Environmental category
Outdoors
Pollution degree outside the inverter
3
Pollution degree inside the inverter
2
Operating temperature range
-25°C to +60°C
Maximum permissible value for relative humid-
ity, non-condensing
100 %