• Plug the RJ45 connector into the surge arrester at the terminal
LINE IN
.
• To connect the Ethernet cable to the next SMA String-Monitor in the communication bus,
plug the other end of the Ethernet cable into the surge arrester for the communication
input in the next SMA String-Monitor at the terminal
LINE IN
.
• To connect the Ethernet cable in the inverter, see inverter manual.
8. Connect the electronic assembly to the surge arrester for the communication input:
• Plug the RJ45 connector on the supplied Ethernet cable into the
EQUIP
terminal of the
surge arrester.
• Connect the other end of the Ethernet cable on the electronic assembly to the String-
Monitor Unit at terminal
X9
according to the circuit diagram. Observe the prescribed
cable route.
• Attach the Ethernet cable in the SMA String-Monitor with the cable brackets.
• Push the mounting tie onto the bracket of
the DC load-break switch and secure the
Ethernet cable in position with the cable tie.
9. For the communication input, connect the surge arrester to the enclosure opening for
communication:
• Route the Ethernet cable for the communication input through enclosure opening for
communication into the SMA String-Monitor. To do this, pierce the membrane and push
the Ethernet cable through the membrane.
• Connect the RJ45 connector to the inserted end of the Ethernet cable in accordance with
EIA/TIA 568B (eight-conductor). Make sure that no pieces of cable are dropped into the
SMA String-Monitor.
• Route the Ethernet cable to the surge arrester in the cable channel according to the cable
route. To do this, remove the cover of the cable channel, lay the Ethernet cable inside and
reattach the cover.
• Plug the RJ45 connector into the surge arrester at the terminal
LINE IN
.
10. Remount the protective covers in the SMA String-Monitor.
11. Switch the SMA String-Monitor back on.
4 Installation
SMA Solar Technology AG
Installation Manual
SSMAbleitKomm-IA-xx-11
28
ENGLISH
Содержание SSM-U-COMOVP
Страница 108: ...1 1 1 SSM U COMOVP Ethernet SMA String Monitor 1 2 1 3 1 SMA Solar Technology AG SSMAbleitKomm IA xx 11 108...
Страница 110: ...2 2 DC DC DC DC DC 5 3 22 3 SMA Solar Technology AG SSMAbleitKomm IA xx 11 110...
Страница 112: ...F DC G 230 VAC H 4 SMA Solar Technology AG SSMAbleitKomm IA xx 11 112...
Страница 113: ...4 2 24 SMA String Monitor SSM U XX10 A B C 4 SMA Solar Technology AG 113 SSMAbleitKomm IA xx 11...
Страница 123: ...1 1 1 SSM U COMOVP SMA String Monitor 1 2 1 3 1 SMA Solar Technology AG 123 SSMAbleitKomm IA xx 11...
Страница 125: ...3 25 A 1 2 B 1 RJ 45 C 1 RJ45 D 1 E 1 F 1 3 SMA Solar Technology AG 125 SSMAbleitKomm IA xx 11...
Страница 127: ...4 2 27 SMA String Monitor SSM U XX10 A B C D E 4 SMA Solar Technology AG 127 SSMAbleitKomm IA xx 11...
Страница 135: ......
Страница 136: ...SMA Solar Technology www SMA Solar com...