1. NOTES ON SAFETY
Installation, mounting or works on the electrical connection may
only be carried out by an approved electrician.
Do not cover the product - provide free air circulation!
Do not hang or fasten anything on the product, especially no
decoration.
Keep children away from the product.
The luminaire may only be operated with an intact protection glass.
Operate the product only when it functions properly:
In case of a
malfunction
you may
NOT
touch the product or operate it
further. Disconnect the product from the power supply by an external
switch or by the fuse.
If touched or further operated there is
danger from electric shock,
burning, or fire.
A
malfunction
exists when:
visible damages appear.
the product does not work properly (e.g. flickering).
smoke, steam or crackling sounds appear.
smell of burning is recognisable.
an overheating is recognisable (e.g. by discolouration of adjacent
surfaces).
Operate the product only after maintenance and examination by an
approved electrician!
2. USE AS DIRECTED
This product serves exclusively lighting purposes and may:
only be used with a voltage of
230V ~50Hz
.
only be operated when firmly mounted.
not be exposed to strong mechanical loads or to strong
contamination.
only be installed and operated after a condition inspection if the
product is dirty or has been moistened through storage.
not be modified or converted.
3. OPERATION
Exchange the light source always before it reaches its lifespan, to avoid
personal injuries, or damages of the fixture or other objects.
Disconnect the product from the power supply
, before you exchange
the bulbs. Let the
light source cool down
before replacement.
There exists danger of burning!
Use only light sources that are approved for the product. Approved light
sources are indicated on the type label.
Other types of light sources may cause
fire risk
,
damage the product
or
lead to malfunction
.
Replacing the light source:
see Installation.
Check and clean the gasket after each opening of the fixture. The
bearing surface of the gasket must be free of dirt. These measures
ensure that the IP class is maintained.
Note the proper fit for the gasket.
4. MAINTANANCE AND CARE
The following enviromental influences may have unwanted effects on
the surface of the product:
acid rain and sour soil
high salt content in the air
thawing salt
cleaning agents
fertilizer especially in flowerbeds
other chemical substances (e.g. herbicides)
Protect the product by adequate means to avoid unwanted changes of the
surface.
Disconnect the product from the power supply
and let it
cool down
,
before you clean the product.
If disregarded there may be
danger of electric shock
or by
burning
when cleaning the product.
Cleaning:
Clean the product on a regular basis using a slightly
moistened, soft and fluff-free cloth. Please also note additional supplied
notes on maintanance and care.
5. ADDITIONAL IMPORTANT NOTES
Storage:
The product must be stored in a dry and clean environment. Do
not strain the product mechanically during storage.
Warranty:
In case of a warranty contact your dealer.
Disposal:
Notes on the correct disposal in Germany are found on
www.slv.de.
6. INSTALLATION
(only by an approved electrician)
Switch off the mains
or respectively the connection lead before doing
any works
.
There exists
mortal danger from an electric shock
.
Use only parts, which are supplied with the product or are described as
accessories
!
Otherwise the product or the whole installation may not be secure.
Danger for life or danger of fire may exist!
Inspect the product for
loose parts
inside the housing. When there are
loose parts inside the housing and these are not explicitly described the
product may not be installed or operated.
The housing maybe voltage-carrying.
Danger of electric shock!
Use the supplied
fastening material
only when it is suited for the
installation background. If this is not the case use only fastening material
suiting the installation background.
When using fastening material that is not suitable there may be
danger from falling objects.
Unpacking
Consignment:
Three protective tubes
Fastening materials
Carefully take the product out of the packaging removing any transport
safeguards.
Before disposal of the packaging material make sure that all
components of the product are removed.
Installation place
The product is suited for
floor installation
.
Choose a place where the installation is not a source of danger (e.g.
stumbling, knocking).
Make sure that the product is mounted on a
stable, even and tilt-fixed
background
.
Separate Installation Steps
Notice:
Do not try to seal the product yourself, using additional silicon or
another sealant.
Remove the rubber mat from the bottom of the fitting.
Remove the plate for electrical connection from the fitting by loosening
the screws.
1. Direct installation:
Determine the place of installation and mark the holes to be drilled. Note
that the cable outlet of the mains supply corresponds with the cable inlet
of the fixture. Do not damage the power supply line, e.g. by drilling,
screws or strong bending.
Establish the electrical connection (see below).
Attach the plate for electrical connection back on the fitting. Note the
proper fit for the gasket.
Do not forget to apply the toothed washers!
Fix the rubber mat again.
Fasten the fitting on the mounting surface.
2. Installation with earth spike art.-no. 229861 (accessory):
Establish the electrical connection (see below).
Attach the plate for electrical connection back on the fitting. Note the
proper fit for the gasket.
Do not forget to apply the toothed washers!
Fix the rubber mat again.
Fix the earth spike with the enclosed fastening material on the fitting.
Push the earth spike into the ground, until the fitting is kept securely.
3. Installation with concrete anchors art.-no. 229860 (accessory):
Prepare a concrete foundation.
Screw the anchors so far into the mounting plate as shown on the figure.
Direct the connection in sufficient length through the opening of the
mounting plate.
Press the anchors into the fresh concrete, until the mounting plate lies
evenly on the surface. After the concrete hardened the fittig can befixed.
Establish the electrical connection (see below).
Attach the plate for electrical connection back on the fitting. Note the
proper fit for the gasket.
Do not forget to apply the toothed washers!
Fix the rubber mat again.
Fasten the fitting with the nuts on the mounting plate.
Electrical Connection
Direct the connection in sufficient length lead first through the opening
of the rubber mat and than through the cable screwing.
The product must be able to be separated by an all pole separation
from the current supply.
Equip the three wire ends with protective tubes.
For electric connection attach the black or brown wire (live conductor)
of the mains supply with the
clamp L
and the blue wire (neutral
conductor) of the mains supply with the
clamp N
. The green-yellow
wire (protective conductor) of the mains supply has to be tightly
screwed into the
earth clamp
of the product.
Secure the cable screwing using a suitable tool.
Use the second cable screwing for through-wiring.
If you do not wire through, close the not required cable screwing with
the enclosed peg.
Inserting the light source:
Remove the lamp head. Touch
energy-
saving-lamps
on the plastic housing, not on the bulb glass. Screw the
bulb into the socket. Put the lamp head back on. Note the proper fit for
the gasket.
Check if the product functions properly and is securely fixed.
The product is now ready for operation.
art.-no. 232256/66/76
09/2010
© SLV Elektronik GmbH, Daimlerstr. 21-23, 52531 Übach-
Palenberg, Germany, Tel. +49 (0)2451 4833-0
Technical Details are subject to change.
SLV Elektronik GmbH
ENGLISH
OPERATING MANUAL FOR
OUTDOOR FITTING
ROX ACRYL POLE