6. ADJUST WATER FLOW

Flushometer is shipped with the flow control adjustment turned OFF.  

A.

 Disconnect Flushometer Solenoid connector from the Sensor Assembly. Pull on end connector to prevent damage to wires. 

B.

 Lift the Sensor Assembly Override Button up to access the activation assembly.

C.

Open water flow by turning activation assembly slowly COUNTERCLOCKWISE using adjusting tool and a screwdriver or a wrench.

MAKE SURE SOLENOID CONNECTOR GOES THROUGH THE CENTER 

OF THE ADJUSTING TOOL TO AVOID DAMAGE TO THE CABLE.

!!! NOTE !!!

D.

Connect Flushometer Solenoid connector to the Sensor Assembly. 

E.

 Activate Flushometer by pressing the Override Button.  

F.

 Adjust Activation Assembly after each flush until the flow rate delivered properly cleanses the fixture (turn 

CLOCKWISE

 to lessen flow and   

   

COUNTERCLOCKWISE

 to increase flow).

MAKE SURE FLUSHOMETER SOLENOID CONNECTOR IS 

DISCONNECTED FROM SENSOR ASSEMBLY EVERY TIME 

BEFORE ROTATING ACTIVATION ASSEMBLY.

!!! NOTE !!!

THE FLUSHOMETER IS ENGINEERED FOR QUIET OPERATION. 

EXCESSIVE WATER FLOW CREATES NOISE, WHILE TOO 

LITTLE WATER FLOW MAY NOT SATISFY THE NEEDS OF THE 

FIXTURE. PROPER ADJUSTMENT IS MADE WHEN PLUMBING 

FIXTURE IS CLEANSED AFTER EACH FLUSH WITHOUT 
SPLASHING WATER OUT FROM THE LIP AND A QUIET 

FLUSHING CYCLE IS ACHIEVED.

!!! IMPORTANT !!!

THE ACTIVATION ASSEMBLY SHOULD NEVER BE OPENED TO 

THE POINT WHERE THE FLOW FROM THE VALVE EXCEEDS 

THE FLOW CAPABILITY OF THE FIXTURE. IN THE EVENT 

OF A VALVE FAILURE, THE FIXTURE MUST BE ABLE TO 

ACCOMMODATE A CONTINUOUS FLOW FROM THE VALVE.

!!! IMPORTANT !!!

Decrease Flow

Increase Flow

Pass Solenoid Cable 

through to avoid damage

7. INSTALL WALL PLATE

Flushometer is shipped with the  flow control adjustment turned 

OFF

.  

A.

 Make sure retaining screw on bracket is fully tightened

B. 

Slide Sensor Assembly all the way up.

C.

 Align Wall Plate cut out with the window and Override Button of Sensor Assembly and push Wall Plate all the way in. 

    i.Make sure sensor window and button are sitting inside the wall plate cut out.

D.

 Slide Wall Plate all the way down.

E.

 Unscrew the retaining screw using supplied Allen key until it touches wall plate.

F. 

Make sure Wall Plate doesn’t slide up.

A.

Retaining Screw

C.

E.

DO NOT UNSCREW ANYMORE ONCE SCREW 

TOUCHES WALL PLATE.

!!! NOTE !!!

B.

UNDER NO CIRCUMSTANCES SHOULD THE SOLENOID BE 

REMOVED OR ADJUSTED.

!!! NOTE !!!

1

2

Содержание TRF 8156-1.28

Страница 1: ...8156 1 6 TRF 8156 1 28 TRF 8156 1 1 TRF 8196 0 5 TRF 8196 0 25 TRF 8196 0 125 PRIOR TO INSTALLATION TOOLS REQUIRED FOR INSTALLATION Smooth jawed wrench at least 2 Phillips screwdriver 5 64 hex wrench...

Страница 2: ...jaw wrench D Connect outlet pipe not porvided to flushometer Tighten securely with fixed jaw wrench NOTE DO NOT EXERT FORCE ON WALL BOX TO TIGHTEN THE FLUSHOMETER USE FIXED JAW WRENCH TO HOLD THE VALV...

Страница 3: ...f the pipe C Remove mud guard by removing the 2 50 mm long truss head screws and discard mud guard NOTE WALL PLATE OPENING MUST BE OF 5 6 X 5 6 142 X 142 MM D Install wall bracket onto flushometer usi...

Страница 4: ...racket i Align the 4 slots on the Sensor Assembly with the mounting pegs on the Wall Bracket ii Slide the Sensor Assembly all the way down For Hardwire connection use i Using a wire stripper strip the...

Страница 5: ...tart up routine is complete B After the start up routine is complete in the first ten 10 minutes of operation a visible Red LED flashes in the Sensor Window of the TruFlush Flushometer when a user is...

Страница 6: ...TTLE WATER FLOW MAY NOT SATISFY THE NEEDS OF THE FIXTURE PROPER ADJUSTMENT IS MADE WHEN PLUMBING FIXTURE IS CLEANSED AFTER EACH FLUSH WITHOUT SPLASHING WATER OUT FROM THE LIP AND A QUIET FLUSHING CYCL...

Страница 7: ...m Urinal Models 15 to 34 381 mm to 864 mm The Factory setting should be satisfactory for most installations If the range is too short i e not picking up users or too long i e picking up opposite wall...

Страница 8: ...assembly to the solenoid and then press the Override Button to relieve pressure H Disconnect Flushometer solenoid connector from the Sensor Assembly pull on end connector to prevent damage to wires li...

Страница 9: ...ee Section 6 Q Put down the Sensor Assembly Override Button R Install Wall Plate See Section 7 13 TROUBLESHOOTING A Sensor Flashes Continuously Only When User Steps Within Range i Unit in Start Up mod...

Страница 10: ...Valve Assembly 0 5 gpf 1 9 Lpf 3400108 TRF 8196 0 25 LP Sensor Valve Assembly 0 25 gpf 1 0 Lpf 3400109 TRF 8196 0 125 LP Sensor Valve Assembly 0 125 gpf 0 5 Lpf VALVE ASSEMBLY SELECTION GUIDE Filter S...

Страница 11: ...No 1 See Table Valve Assembly Less Plate Page 10 2 See Table Piston Assembly Page 10 3 See Table Activation Assembly Page 10 4a Wall Plate Assembly Sensor Closet 4b Wall Plate Assembly Sensor Urinal...

Отзывы: