HOT LIMIT STOP ADJUSTMENT
OPERATION
CARE AND CLEANING
DO NOT USE
abrasive or chemical cleaners (including chlorine bleach) to clean
faucets that may dull the luster and attack the chrome or special decorative
fi nishes. Use
ONLY
mild soap and water, then wipe dry with clean cloth or towel.
While cleaning the bathroom tile, protect the faucet from any splattering of
cleaner. Acids and cleaning fl uids will discolor or remove chrome plating.
As the user’s hands enter the beam’s effective range, the beam is refl ected
back into the sensor receiver and activates the solenoid valve allowing water
to fl ow from the faucet. Water will fl ow until the hands are removed or until the
faucet reaches its automatic time out setting.
A
C
D
TROUBLESHOOTING GUIDE
1. Problem
Faucet does not function.
Cause
Adhesive packaging label affi xed over sensor eye.
Solution
Remove adhesive label from sensor eye.
Cause
Permanent Off Activated shown by RED fl ashing LED.
Solution
Touch button on sensor window for 2 seconds, RED fl ashing
LED will stop and confi rmed with GREEN LED.
2. Problem
Faucet delivers water in an uncontrolled manner.
Cause
Faucet is defective.
Solution
Contact Sloan Technical Support (see below).
3. Problem
Faucet does not deliver any water with hands in sensor
range.
Indicator Solenoid valve produces an audible “click.”
Cause
Water supply stop(s) closed.
Solution
Open water supply stop(s).
Cause
Water supply stop strainer(s) clogged.
Solution
Turn off water at supply stop(s). Remove, clean and reinstall
water supply stop strainer(s). Replace strainer(s), if required.
Turn on water at supply stop(s).
Indicator Solenoid valve does not produces an audible “click.”
Cause
Battery low.
Solution
Replace battery (refer to battery replacement).
Solution
Contact Sloan Technical Support (see below)
4. Problem
After removing label water does not fl ow.
Use this installation guide as a target by placing it in front of the
sensor (approx. 1-1/2” away) until water begins fl owing, then
remove installation instruction from sensor.
Water will stop fl owing, wait 10 seconds before using faucet.
5. Problem
Faucet delivers only a slow fl ow or dribble when sensor
is activated.
Cause
Water supply stop(s) are partially closed.
Solution
Completely open water supply stop(s).
Cause
Water supply stop strainer(s) clogged.
Solution Turn off water at supply stop(s). Remove, clean and reinstall
water supply stop strainer(s). Replace strainer(s), if required.
Turn on water at supply stop(s).
Cause
Spray head is clogged.
Solution Remove, clean, and reinstall spray head. Replace spray head, if
required.
Cause
Faucet is defective.
Solution
Contact Sloan Technical Support (see below).
6. Problem
Faucet does not stop delivering water or continues to
drip after user is no longer detected.
Cause
Faucet is defective.
Solution
Contact Sloan Technical Support (see below).
7. Problem
LED indicator blinks RED when faucet is in use.
Cause
Battery low.
Solution
Replace battery (refer to battery replacement)
8. Problem
The water temperature is too hot or too cold on a faucet
connected to hot and cold supply lines.
Cause
Supply stops are not adjusted properly.
Solution
Adjust supply stops.
Cause
For models with integral mixing valve – Mixing valve is set
improperly for the water temperature desired.
Solution Rotate mixing valve handle clockwise to decrease water
temperature or counterclockwise to increase water
temperature.
When assistance is required, please contact Sloan Technical Support at:
1-888-SLOAN-14 (1-888-756-2614)
Close supply stop(s).
B
Loosen screw
with hex wrench
and remove cap.
• Adjust temperature to desired limit
• Adjust screw to meet limit setting
Replace cover
and tighten screw
with hex wrench.
E
Open
supply stop(s).
Wait ten (10) seconds
before using faucet.
10 Sec.
F