Installation Instructions

Code #: 0816885 Draft: 7.0 (10/20)

Initial Setup Prior to First Use

IMPORTANT

(Must be completed before initial power up and water connection)

 

•  Use holding tank cleaner/treatment for 16 gallon waste tank.

•  Sanitation of the fresh water pump (if applicable) must be completed prior to initial use.

•  Batteries for the paper towel dispenser are shipped loose and must be installed prior to initial use.

•  Soap bottle is shipped loose and must be installed prior to initial use.

This mobile handwashing sink has multiple options for power, water supply, and drainage. See below.

Power

•  AC Power

 

Select this option when power can be supplied by an external source.

•  DC Power (If applicable)

 

Select this option when external power is not available, and battery power is required. 

Water Supply

•  External Water Supply

 

Select this option when external water connection is available, this option can be connected via a 3/4” 

garden hose.

•  5 Gallon Water Supply (If applicable)

 

Select this option when external water connection is not available, two 5 gallon water bottles (not supplied) 

are required.

Drainage

•  Manual (Gravity fed)

 

Select this option if no power is available to the unit. This option is controlled by a ball valve.

•  Electric Pump

 

Select this option select this option if AC or DC power has been select, this option is controlled by a switch.

 

Select this option if waste needs to be pumped up hill or over a long distance. 

Faucet:

•  Refer to detailed EFX-150 instructions available via Sloan.com for the following:

 

Sensor calibration (If required)

Note:

 Failure to properly calibrate the faucet sensor may lead to unexpected activation and increase 

maintenance intervals.

 

Priming

 

Battery battery replacement

 

Care and cleaning

Soap Dispenser:

•  Refer to detailed CS-8 instructions available via GOJO.com for the following:

 

Installation of replacement soap bottle and battery (Shipped together)

 

Care and cleaning

Paper Towel Dispenser:

•  Refer to EnMotion manufacturer instructions for the following:

 

Installation of batteries (Included, shipped loose)

 

Paper towel installation

 

Paper length setting

 

Care and cleaning

Fresh Water Pump:

 

•  Refer to detailed instructions available via Xylem.com for the following:

 

Sanitize unit prior to first use.

 

Routine sanitation must occur as required, minimum 6 times per year.

16 Gallon Waste Tank

•  Sanitation of Grey Water Tank

 

The 16 Gallon grey water tank must be treated to break down waste and eliminate odors. Using a liquid 

holding tank cleaner/treatment, follow the holding tank cleaner instructions for cleaning or treatment of grey 

water holding tank.  For best results, clean and flush the tank weekly regardless of the water level or usage. 

Recommend using a formaldehyde-free formulation that is safe for all pipes including PVC. Routine treatment 

is an important step to ensure reliable service.

Содержание MH-3050

Страница 1: ...eriod Sloan Valve Company will at its option repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company at customer s cost and this shall be the sole remed...

Страница 2: ...of 11 Installation Instructions Code 0816885 Draft 7 0 10 20 Parts List Description Item Number Quantity Panel Lower Front 1 1 Panel Left 2 1 1 4 Hex Key Not Shown 3 1 Paper Towel Key Tool Not Shown 4...

Страница 3: ...Pull Handle Handle for moving unit around facility AC Power In 3 Prong Twist Lock Water Supply In 3 4 garden hose connection Waste Water Out 3 4 garden hose connection AC DC On Off 3 way toggle switch...

Страница 4: ...Select this option select this option if AC or DC power has been select this option is controlled by a switch Select this option if waste needs to be pumped up hill or over a long distance Faucet Ref...

Страница 5: ...the Rapid Response Wash Station d Make sure that connection is tight and does not leak 2 Connect to waste line out Gravity Fed a Using a standard 3 4 yard hose or equivalent connect to the Waste Line...

Страница 6: ...rong NEMA L5 20 AMP 125V Power cord Not supplied into twist lock AC Power In receptacle on the rear panel of the Mobile Handwashing Sink and connect the opposite end to a matching NEMA L5 20R twist lo...

Страница 7: ...er until the lever locks in the open position and the caster rotates freely 3 Connect external water supply in and the waste line out 4 Plug a 12 3 Prong NEMA L5 20 AMP 125V Power cord Not supplied in...

Страница 8: ...r not shown for clarity 1 Drain the waste tank Gravity Fed a Make sure that waste line hose is connected to waste line out Gravity Fed Location Figure 3 page 5 at the bottom rear panel of the Rapid Re...

Страница 9: ...ear panel of the Mobile Handwashing Sink b Make sure that the opposite end of the waste line hose is in an appropriate location to drain the waste water tank 16 gallons minimum drainage c Use the 1 4...

Страница 10: ...brushes files or other steel tools to clean stainless steel Certain chemical compounds if used on stainless steel can give the appearance of rust and if allowed to stand for long periods of time can...

Страница 11: ...2B 0383301 PURELL CS8 1200 mL HEALTHY SOAP refill 2pk 3 0383332 Georgia Pacific enMotion Impulse Automatic Paper Towel Dispenser White 4 0383505 Pull Handle 5 0383390 Trash bag Holder 6 0383518 Graphi...

Отзывы: