45
6461
2
2022
-
SPS-B
MG_0294
WARNING
Do NOT cut the protection cover
Lock nut
- 14.3 mm
- .56”
Allen key
- 4.8 mm
- .19”
4
3
Fin Installation
Installation of the fi n assemblies
1. Place correct fi n on a pallet adjacent to relevant actuator under the yacht for mounting.
2. Locate port and starboard fi n valve units.
3. On the fi n valve units locate the manual decouple valve.
(
Relevant only, if you do not have any electrical or hydraulic power installed yet)
- Unlock the valve by turning the 9/16” lock nut anti-clockwise.
- Open the valve by turning the 3/16” Allen key anti-clockwise.
4.
Remove protective covering from the actuator shaft. Clean and degrease the angled surface.
(NB: The protective cover can easily be removed by
blowing air using a air pressure gun into the bottom hole of the cover.)
MC_0255
WARNING
A hand oil pump (Installation tool kit, Item nr VFT55) must be used to achieve the fi n installation. The pump should only be operated by
qualifi ed personnel that follow the pump manual operating instruction and health and safety directives.
Fin Installation
5. Remove shaft covers from fi n using a 4mm Allen key.
6. Use a suitable tool to move the actuator to the most outboard position, without damaging the shaft. Checking on the actuator that the cylinders
are in the outboard position (inboard will be fully aft, outboard will be fully forward). Ensure that the actuator stays in the outboard position when
fi n is being installed.
7.
- Remove the transportation protection from the Stabilizer fi n assembly.
- Unscrew all nuts and washers.
- Inspect and clean the internal hub.
MC_0255
MG_0295
Ø10.2
Ø10.2
54 mm
Tool
5
6
7