4
2728
13
2021
-
SEP 80 & 100 & 120 & 130 & 150
MC_0124
Thruster Measurements
EN
Measurement
code
Measurement description
mm inch mm inch mm inch mm inch mm inch mm inch mm inch
ID
Internal tunnel diameter
185
7,28
185
7,28
185
7,28
185
7,28
215
8,46
250
9,84
250
9,84
H
Motor Height
352
13,86
344
13,54
393
15,47
393
15,47
394
15,51
398
15,67
398
15,67
W
Width
252
9,92
261
10,28
292
11,50
272
10,71
266
10,47
296
11,65
277
10,91
L
Length
206
8,11
206
8,11
240
9,45
240
9,45
243
9,57
250
9,84
249
9,80
WD
Water Depth
185
7,28
185
7,28
185
7,28
185
7,28
215
8,46
250
9,84
250
9,84
TL
Minimum tunnel length
179
7,05
179
7,05
179
7,05
179
7,05
233
9,17
253
9,96
253
9,96
TL (recommended)
Recommended tunnel length
216
8,50
216
8,50
216
8,50
216
8,50
276
10,87
303
11,93
303
11,93
T (min)
Minimum tunnel wall thickness
6
0,24
6
0,24
6
0,24
6
0,24
7
0,28
7
0,28
7
0,28
T (max)
Maximum tunnel wall thickness
8
0,31
8
0,31
8
0,31
8
0,31
9
0,35
9
0,35
9
0,35
Measurement
code
Measurement description
mm inch
ID
Internal tunnel diameter
215
8,46
H
Motor Height
412
16,22
W
Width
292
11,50
L
Length
245
9,65
WD
Water Depth
215
8,46
TL
Minimum tunnel length
233
9,17
TL (recommended)
Recommended tunnel length
276
10,87
T (min)
Minimum tunnel wall thickness
7
0,28
T (max)
Maximum tunnel wall thickness
9
0,35
*80
12v
*150
24v
*100
12v
*120
24v
*80
24v
*100
24v
*130
12v
*130
24v
*Valid for SE & SEP
MC_0138
Thruster Specifi cations
EN
Description
* 80
* 100
* 120
* 130
* 150
Available DC System (v)
12v & 24v
12v & 24v
24v
12v & 24v
24v
Thrust 12v or 24v (kg * lbs)
96 kg * 212 lbs
116 kg * 256 lbs
139 kg * 306 lbs
160 kg * 352 lbs
182 kg * 400 lbs
Thrust 10.5v or 21v (kg * lbs)
80 kg * 176 lbs
100 kg * 220 lbs
120 kg * 264 lbs
130 kg * 284 lbs
150 kg * 330 lbs
Typical Boat Size (m * ft)
10m - 15m * 35ft - 48ft
12m - 17m * 35ft - 15ft
13m - 18m * 42ft - 60ft
13m - 19m * 42ft - 62ft
14m - 20m * 44ft - 64ft
Propulsion System
Twin
Twin
Twin
Twin
Twin
Power (kw * Hp)
4.4kw * 6hp
6.3kw * 8.4hp
6.4kw * 8.55hp
6.5kw * 8.7hp
8.8kw * 11.8hp
Weight (kg * lbs)
20kg * 44lbs
31kg * 68lbs
34kg * 74lbs
37kg * 77lbs
38kg * 79lbs
*Valid for SE / SE IP & SEP / SEP IP
MG_0075
TL
WD
H
W
L
ID
T
Tunnel centre line
Twin Propeller
The gear leg/ propeller(s) must
never extend out of the tunnel
Propeller position will vary
with each thruster model
MC_0055
Proportional Technical Specifi cations
EN
Safety features:
- The PPC Speed Control unit will turn off motor power each time the main solenoids are activated. This removes any possibility for
solenoid lock-in. Any fault in the main solenoids will give feedback to the panel and turn off power to the electric motor.
MC_0051
Technical Specifi cations
EN
Motor:
Custom made reversible DC-motor.
Gear house:
Seawater resistant bronze. Ball-bearing at propeller shaft and a combination of ball bearing and slide bearing at drive shaft.
(Pre-fi lled and sealed for life)
Motor bracket:
Glass fi bre reinforced composite material. Brass thread inserts.
Tunnel:
Cross spun with rowing G.R.P tunnel
Steel & aluminium tunnels available at request.
Propeller:
5-blade skewback “Q-prop” propeller, fi breglass reinforced composite.
Batteries:
Minimum recommended battery capacity (cold crank capacity by DIN/SAE standard)
Contact a battery supplier for more information.
Max. Use:
2 - 3 min. duty cycle at 20°C
Safety features:
- Electronic time-lapse device protects against sudden change of drive direction.
- The electric thermal cut-off switch in electro motor protects against overheating (auto-reset when electro motor cools down).
- Flexible coupling between electro-motor and drive shaft protects electro motor and gear system if propeller jams.
- Original Sleipner panels shut off automatically 6 minutes after last use. This interval can be adjusted in 5 min steps up to 60
minutes or turned off completely.
- Original Sleipner panels use child-safe double ON buttons.
- An integrated microprocessor monitors solenoids, reduce wear and risk of solenoid lock-in.
- Auto-stop of the thruster occurs when an undesirable solenoid lock-in occurs or when continuous operation cut-off timer
exceeds 3 minutes.