Slant/Fin GAS Modular Boilers Скачать руководство пользователя страница 6

6

EQUIPMENT INCLUDED
GGT SERIES — Hot Water Models

One per module unless otherwise noted

• Pre-assembled heat exchangers with built-in air separators

and insulated jacket.

• Base.
• Flue collector.
• Gas burners, gas orifices and manifold assembly.
• Combination gas valve including manual shut-off pressure 

regulator.

• Pilot adjustment and automatic pilot-thermocouple safety.
• Hi-limit control.
• System pressure and temperature gauge (unmounted, one 

per system).

• Module pressure and temperature gauge (unmounted).
• Module pressure relief valve (ASME) (unmounted). Specify 

30, 50 or 100 psi.

• Control header (unmounted, one per system).
• Draft hoods (unmounted).

OPTIONAL EQUIPMENT

• Hot water supply and return header assemblies.
• Control panel with automatic lead lag.
• Spark ignition system.
• Vent dampers.
• External DHW heat exchanger.

Figure 6. Gas Caravan—optional header assembly for all models GGT hot water Caravan systems

*Building piping must be rigidly secured so it cannot    

move where connected to headers.

NOTE:
Shown reverse return (Preferred). For direct return,
header assembly piping connections may be made at
the same end of the boiler bank, not as shown.

Some governing agencies do not allow compression
type couplings. Consult your local code requirements.

 

Содержание GAS Modular Boilers

Страница 1: ...The unit must be electrically grounded if an external power source is used In Canada the installation must be in accordance with standards CGA B149 1 and B149 2 installation codes for gas burning appl...

Страница 2: ......

Страница 3: ...2275 78 1 82 4 4880 301 16 625 8 10 1323 32 253 16 115 16 21 2 3 GGHT 3375E 9 GG 375HEC 3375 2736 15860 2379 81 7 92 7 5490 301 16 595 8 10 1323 32 253 16 115 16 23 10 3 GGHT 3600E 9 GG 399HEC 3591 29...

Страница 4: ...4 Design Data Max ASME Working Pressure 100 psi Power Requirements 120 volts 60 HZ 34 amps per module Figure 1 Gas Caravan dimensions and typical piping hot water models...

Страница 5: ...r piping for variable circulation Figure 3 Supply and return piping locations Figure 4 Instantaneous tankless coil two temperature with recirculation Figure 5 Storage tank from tankless coil with reci...

Страница 6: ...lief valve ASME unmounted Specify 30 50 or 100 psi Control header unmounted one per system Draft hoods unmounted OPTIONAL EQUIPMENT Hot water supply and return header assemblies Control panel with aut...

Страница 7: ...opening near the floor below burner air inlet and one louvered opening near the ceiling above the highest draft regulator each opening with a minimum FREE air passage area of 1 square inch per 4000 B...

Страница 8: ...8 Figure 8 Typical layouts for gas fired systems...

Страница 9: ...uld be used where permitted for additional protection against adverse wind conditions and precipitation The National Board of Fire Underwriters recommend that the chimney should extend at least 3 feet...

Страница 10: ...ation of this pipe in a typical appli cation Table 2a depicts the proper diameter Dim C of the connector rise depending upon its total length top of the draft hoods to the breeching above GG 200C 7 7...

Страница 11: ...057 4 68 2 11 2 34 3 11 1 1 4 2 19 1 37 1 07 0 082 6 54 2 94 3 27 4 35 1 1 2 2 63 1 64 1 29 0 098 7 84 3 52 3 92 5 21 2 3 55 2 23 1 74 1 320 10 60 4 77 5 30 7 05 3 5 72 3 59 2 81 2 130 17 08 7 69 8 8...

Страница 12: ...3 068 8 500 5 900 4 700 4 100 3 600 3 250 3 000 4 4 026 17 500 12 000 9 700 8 300 7 400 6 800 6 200 80 90 100 125 150 175 200 1 4 364 11 10 9 8 8 7 6 3 8 493 23 22 21 18 17 15 14 1 2 622 43 40 38 34 3...

Страница 13: ...The view menu on the control includes error messages actual outdoor air temperature actual supply water temperature target supply water temperature and running time for each stage This control can be...

Страница 14: ...Plastic tie straps Other Options include Immersion well for supply water sensor to be installed in control header supplied with Caravan High Limit manual reset and Immersion Well to be installed in co...

Страница 15: ...15 FIELD WIRING AT MODULES...

Страница 16: ...16 SC 3 SYSTEM WIRING DIAGRAM...

Страница 17: ...17 SC 3 LADDER WIRING DIAGRAM...

Страница 18: ...18 SC 9 SPACE HEATING WIRING DIAGRAM...

Страница 19: ...19 SC 9 SPACE HEATING LADDER WIRING DIAGRAM...

Страница 20: ...20 SC 9 SPACE AND DOMESTIC HOT WATER WIRING DIAGRAM...

Страница 21: ...21 SC 9 SPACE AND DOMESTIC HOT WATER LADDER WIRING DIAGRAM...

Страница 22: ...base jacket insulation combustion chamber tankless heater exhaust and air inlet piping burner enclosure mixing elbow gas and air orifice blower assem bly air filter and electrical and mechanical comp...

Страница 23: ...CARAVAN SYSTEM RATING PLATE System rating plate format for Caravan modular boiler system System rating plates are available upon request using the form on the back cover...

Страница 24: ...N Y 11548 Phone 516 484 2600 FAX 516 484 5921 Canada Slant Fin LTD LTEE Mississauga Ontario www slantfin com Each individual Caravan module is shipped with a rating plate bearing the model serial numb...

Отзывы: