Slant/Fin GAS Modular Boilers Скачать руководство пользователя страница 22

WARRANTY INCLUDES:
FIRST YEAR:

Repair or replacement in accordance with

warranty service procedure, for a period of one year after
original installation, of all parts found to be defectively 
manufactured.

WARRANTY INCLUDES:
SECOND THROUGH FIFTH YEAR:

Repair or replacement

for the second through fifth year after original installation, of
cast iron heat exchanger found to be defectively manufac-
tured, at no cost for the replacement part. The repaired or
exchanged part will be warranted for only the unexpired 
portion of the original warranty.

This warranty extends only to boilers in space heating 
applications. See “Additional Warranty Terms” section for
more details.

Warranty extends only to boilers which have been properly
installed, operated and maintained in accordance with
Slant/Fin installation instructions and all applicable codes.
Warranty applies only if the boiler has remained at all times
in the location at which it was originally installed. Slant/Fin
makes no express warranties other than the warranties 
contained herein.

WARRANTY EXCLUDES:

All labor charges incurred by any person in connection with
the examination, removal, and repair of parts claimed to be
defective and the installation of replacement parts.

The part claimed to be defective shall be returned to
Slant/Fin. The cost of shipment to Slant/Fin is borne by the
consumer.

Damage caused by water that contains excessive lime,
calcium, or other contaminants.

Boilers operated with combustion air that may be 
contaminated by chemicals or improper fuel additives.

Improper burner adjustments, control settings or 
maintenance procedures.

NOTE

: Boilers are to be used in closed systems. Any 

application that causes significant quantities of fresh make
up water to enter the system is not permitted. Such 
applications can be met with a heat exchanger that will
maintain the boilers in a closed system.

AFTER FIRST YEAR, WARRANTY EXCLUDES:

All boiler components other than a cast-iron heat exchanger,
such as, sheet metal base, jacket, insulation, combustion
chamber, tankless heater exhaust and air inlet piping, burner
enclosure, mixing elbow, gas and air orifice, blower assem-
bly, air filter and electrical and mechanical components 
furnished to Slant/Fin by other manufacturers, such as
pumps, relays, controls, gauges, etc.

PROCEDURE FOR WARRANTY SERVICE:

For warranty service, provide the person who installed your
Slant/Fin boiler with the following information: boiler model
number and serial number (from the boiler rating plate) and
the date of installation. That person will notify the Slant/Fin
wholesaler from whom the boiler was purchased.

Part(s) claimed to be defective must be returned through
trade channels and replacement part(s) will, if warranty 
conditions are met, be provided by Slant/Fin through the
wholesaler.

If there are any questions about the coverage of this 
warranty, please contact Slant/Fin at the address shown
below.

LIMITATIONS ON IMPLIED WARRANTIES AND 
DAMAGES:

Slant/Fin assumes no liability for damages or unsatisfactory 
performance of any kind which is a result of improper
installation.

Slant/Fin's sole obligation in the event of a breach of any
implied warranty (including, but not limited to, implied 
warranties of merchantability and fitness for a particular 
purpose) is limited to repair or replacement, and all such
warranties are limited in duration to the period of time after
the date of original installation as stated above.

This warranty does not cover claims for incidental or 
consequential damages resulting from a breach of any
express or implied warranty or any other reason.

Some states do not allow limitations on how long an implied
warranty lasts or the exclusion or limitation of incidental or
consequential damages. So the above limitation or 
exclusion may not apply to you.

THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS
AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH
VARY FROM STATE TO STATE.

Slant/Fin

Limited Five-Year Warranty

for Caravan Modular and Individual Commercial Application 

Cast-iron Hot Water Boilers in Space Heating Applications.

Technical Service Department

Slant/Fin Corporation, 100 Forest Drive at East Hills, Greenvale, N. Y. 11548 • (516) 484-2600

22

Содержание GAS Modular Boilers

Страница 1: ...The unit must be electrically grounded if an external power source is used In Canada the installation must be in accordance with standards CGA B149 1 and B149 2 installation codes for gas burning appl...

Страница 2: ......

Страница 3: ...2275 78 1 82 4 4880 301 16 625 8 10 1323 32 253 16 115 16 21 2 3 GGHT 3375E 9 GG 375HEC 3375 2736 15860 2379 81 7 92 7 5490 301 16 595 8 10 1323 32 253 16 115 16 23 10 3 GGHT 3600E 9 GG 399HEC 3591 29...

Страница 4: ...4 Design Data Max ASME Working Pressure 100 psi Power Requirements 120 volts 60 HZ 34 amps per module Figure 1 Gas Caravan dimensions and typical piping hot water models...

Страница 5: ...r piping for variable circulation Figure 3 Supply and return piping locations Figure 4 Instantaneous tankless coil two temperature with recirculation Figure 5 Storage tank from tankless coil with reci...

Страница 6: ...lief valve ASME unmounted Specify 30 50 or 100 psi Control header unmounted one per system Draft hoods unmounted OPTIONAL EQUIPMENT Hot water supply and return header assemblies Control panel with aut...

Страница 7: ...opening near the floor below burner air inlet and one louvered opening near the ceiling above the highest draft regulator each opening with a minimum FREE air passage area of 1 square inch per 4000 B...

Страница 8: ...8 Figure 8 Typical layouts for gas fired systems...

Страница 9: ...uld be used where permitted for additional protection against adverse wind conditions and precipitation The National Board of Fire Underwriters recommend that the chimney should extend at least 3 feet...

Страница 10: ...ation of this pipe in a typical appli cation Table 2a depicts the proper diameter Dim C of the connector rise depending upon its total length top of the draft hoods to the breeching above GG 200C 7 7...

Страница 11: ...057 4 68 2 11 2 34 3 11 1 1 4 2 19 1 37 1 07 0 082 6 54 2 94 3 27 4 35 1 1 2 2 63 1 64 1 29 0 098 7 84 3 52 3 92 5 21 2 3 55 2 23 1 74 1 320 10 60 4 77 5 30 7 05 3 5 72 3 59 2 81 2 130 17 08 7 69 8 8...

Страница 12: ...3 068 8 500 5 900 4 700 4 100 3 600 3 250 3 000 4 4 026 17 500 12 000 9 700 8 300 7 400 6 800 6 200 80 90 100 125 150 175 200 1 4 364 11 10 9 8 8 7 6 3 8 493 23 22 21 18 17 15 14 1 2 622 43 40 38 34 3...

Страница 13: ...The view menu on the control includes error messages actual outdoor air temperature actual supply water temperature target supply water temperature and running time for each stage This control can be...

Страница 14: ...Plastic tie straps Other Options include Immersion well for supply water sensor to be installed in control header supplied with Caravan High Limit manual reset and Immersion Well to be installed in co...

Страница 15: ...15 FIELD WIRING AT MODULES...

Страница 16: ...16 SC 3 SYSTEM WIRING DIAGRAM...

Страница 17: ...17 SC 3 LADDER WIRING DIAGRAM...

Страница 18: ...18 SC 9 SPACE HEATING WIRING DIAGRAM...

Страница 19: ...19 SC 9 SPACE HEATING LADDER WIRING DIAGRAM...

Страница 20: ...20 SC 9 SPACE AND DOMESTIC HOT WATER WIRING DIAGRAM...

Страница 21: ...21 SC 9 SPACE AND DOMESTIC HOT WATER LADDER WIRING DIAGRAM...

Страница 22: ...base jacket insulation combustion chamber tankless heater exhaust and air inlet piping burner enclosure mixing elbow gas and air orifice blower assem bly air filter and electrical and mechanical comp...

Страница 23: ...CARAVAN SYSTEM RATING PLATE System rating plate format for Caravan modular boiler system System rating plates are available upon request using the form on the back cover...

Страница 24: ...N Y 11548 Phone 516 484 2600 FAX 516 484 5921 Canada Slant Fin LTD LTEE Mississauga Ontario www slantfin com Each individual Caravan module is shipped with a rating plate bearing the model serial numb...

Отзывы: