2. Put the elastic buckle into the metal sheet at the air inlet downside of the unit.
Elastic buckle
Electrical Wiring
a. Wiring Precautions
b. Electrical Wiring
1. For solid core wiring
(1). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation about 25mm (15/16") .
(2). Using a screwdriver, remove the terminal screw(s) on the terminal board.
(3). Using pliers, bend the solid wire to form a loop suitable for the terminal screw.
(4). Shape the loop wire properly, place it on the terminal board and tighten securely with the terminal screw using a screwdriver.
2. For strand wiring
(1). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation about 10mm (3/8") .
(2). Using a screwdriver, remove the terminal screw (s) on the terminal board.
(3). Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped wire end.
(4). Position the round terminal wire, and replace and tighten the terminal screw with a screwdriver.
WARNING!
● Before obtaining access to terminals, all supply circuits must be disconnected.
● The rated voltage of the unit is as shown as table 7.
● Before turning on, verify that the voltage is within the 198~264V range.
● Perform wiring work in accordance with standards so that the air conditioner can be operated safely and positively.
Model
Power Supply
Recommended Cord (pieces×sectional area)
12K
220-240V~,50Hz
4×0.75mm
2
18K
220-240V~,50Hz
4×0.75mm
2
24K
220-240V~,50Hz
4×0.75mm
2
Table 8
Solid wire
Strand wire
Solderless terminal
Insulation laver
Screw with
special washer
Wire
Wire
Terminal
board
Round
terminal
Round
terminal
Insulation tube
Insulation tube
Cord clamp
3. How to fix connection cord and power cord by cord clamp. After passing the connection cord and power cord through the insulation tube,
fasten it with the cord clamp.