84
Removal Procedure
11.Remove fan motor
A:Loose the screws fixed the up propeller housing and
loose the fixed motor rubber mount and then take out the
centrifugal fan assembly.
B:Loose the buckles for propeller housing and then
remove the up and down propeller housing.
C:Loose the fixed screws from hole on the fan motor axis
and remove the centrifugation fan from fan motor axis.
Procedure
Note
10.Remove evaporator
A:
Lift-up evaporator and remove evaporator.
Note: Please check step 6 to remove evaporator, and loose
the fixed screws among evaporator,left plate,right plate and
sealplate, lift-up evaporator and take out liquid pipe and
windpipe from right plate and then remove the evaporator
assembly.
Note: remove the fan motor begin with step 11 and Loose
the fixed screws from hole on the fan motor axis and remove
the centrifugation fan from fan motor axis.
centrifugation fan assembly
down propeller housing
up propeller housing
motor
strap
motor
buckles
fan motor