5
Specifications
Indoor
Unit
Indoor Unit Model
--
SMVH09D-1B1A3NA(I)
SMVH12D-1B1A3NA(I)
Fan Type
--
Cross-flow
Cross-flow
Fan Diameter Length(D×L)
mm
Ф97×673
Ф97×673
Cooling Speed (SH/H/L/SL)
r/min
1250/1150/700/650
1350/1250/750/700
Heating Speed (SH/H/L/SL)
r/min
1250/1150/850/800
1350/1250/900/850
Fan Motor Power Output
W
20
20
Fan Motor RLA
A
0.21
0.21
Evaporator Form
--
Aluminum Fin-copper Tube
Aluminum Fin-copper Tube
Evaporator Pipe Diameter
mm
Ф7
Ф7
Evaporator Row-fin Gap
mm
2-1.4
2-1.4
Evaporator Coil Length (L×D×W)
mm
669×25.4×266
669×25.4×266
Swing Motor Model
--
24BJ-A3
24BJ-A3
Swing Motor Power Output
W
1.5
1.5
Fuse Current
A
3.15
3.15
Set Temperature Range
℃
16
~
31
16
~
31
Sound Pressure Level(SH/H/L/SL)
dB (A)
40/38/21/19
42/39/25/20
Sound Power Level
dB (A)
50/48/31/29
52/49/35/30
Dimension (W×H×D)
mm
910X303X200
910X303X200
Dimension of Carton Box (W×H×D)
mm
994X284X371
994X284X371
Dimension of Package(W×H×D)
mm
997X294X374
997X294X374
Stacked Layers
--
7
7
Net Weight
kg
12
12
Gross Weight
kg
15
15
Outdoor
Unit
Outdoor Unit Model
--
SMVH09D-1B1A3NA(O)
SMVH12D-1B1A3NA(O)
Compressor Trademark
panasonic
panasonic
Compressor Manufacturer
--
panasonic Wanbao Applianc-
es Compressor(guangzhou)
CO.,LTD./panasonic
panasonic Wanbao Applianc-
es Compressor(guangzhou)
CO.,LTD./panasonic
Compressor Model
--
9RS092ZAB21
9RS102ZAA21
Compressor Oil
--
FV50S or FW50S
FV50S or FW50S
Compressor Type
--
Rotary
Rotary
Compressor LRA.
A
20.2
16.5
Compressor RLA
A
6.22
6.48
Compressor Power Input
W
920
970
Fan Type
--
Axial-flow
Axial-flow
Fan Diameter
mm
405
455
Fan Diameter
inch
15.9
17.9
Fan Motor Speed
rpm
880
720
Fan Motor Power Output
W
30
55
Fan Motor RLA
A
0.4
0.47
Outdoor Unit Air Flow Volume
m
3
/h
1800
2800
Condenser Form
--
Aluminum Fin-copper Tube
Aluminum Fin-copper Tube
Condenser Pipe Diameter
mm
Ф7
Ф7
Condenser Rows-fin Gap
mm
2-1.4
2-1.4
Condenser Coil Length (L×D×W)
mm
742×38.1×506
869×38.1×572
Permissible Excessive Operating
Pressure for the Discharge Side
MPa
4.3
4.3
Permissible Excessive Operating
Pressure for the Suction Side
MPa
2.5
2.5
Maximum Allowable Pressure
MPa
4.3
4.3
Cooling Operation Ambient Tem-
perature Range
℃
-15~54
-15~54