13
Function and Control
● During operation, point the remote control signal sender at the receiving window on indoor unit.
● The distance between signal sender and receiving window should be no more than 8m, and there should be no obstacles
between them.
● Signal may be interfered easily in the room where there is fluorescent lamp or wireless telephone; remote controller should be
close to indoor unit during operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the batteries.
● If the display on remote controller is fuzzy or there’s no display, please replace batteries.
NOTE:
Replacement of Batteries
1. Press the back side of remote controller marked with " ", as shown in the fig,and then push out the cover of battery box
along the arrow direction.
2. Installation two 7# (AAA 1.5V) dry batteries, and make sure the position of "+" polar and "-" polar are correct.
3. Reinstall the cover of battery box.
Setting the dehumidifying mode with 30 degree after the unit is powered on within 60s.And then press "LIGHT"
→
"SLEEP"
→
"LIGHT"
→
"SLEEP",it could change the memory to not memory function.The light blink and show the error code 3s.
Memory setting
Press "light" and "-" button together for 3s,It could enter or exit this function.It will show the error code when this function is on.
Display by remote controller
Press the "FAN" and "MODE" 3s at the same time in heating mode,it will enter or exit the
manually defrost.Remote controller will
display "dF" 5s,and it will show the setting temperature after 5s.
Manually defrost
Repowered within 5mins, set 16 degree under cooling mode, then press the "TURBO" button 6 times within 3s, will enter this
function.
Collecting freon
In the heating mode, press "SLEEP" and "TURBO" buttons together for 3s would start or cancel the Timing defrost.
Timing defrost
The minimum cooling temperature setting
In the off mode,pressing "TEMP"and "-" button at the same time,the LCD will display the minimum cooling temperature.The
default temperature is 16°C and you can adjust the temperature with "+" or "-" from 16°C to 31°C, 3 seconds later it will return to
the standby mode.
In the off mode,pressing "TEMP" and "+" button at the same time,the LCD will display the maximum heating temperature.The
default temperature is 31°C and you can modulate the temperature with "+" or "-" from 16°C to 31°C, 3 seconds later it will
return to the standby mode.
● In heating mode, pressing "Mode" and "+" button at the same time will enter/exit the low temperature heating function.
● "LA" would be showed on the remote controller after entered into the low temperature heating funtion.
● When switching from one mode to another mode, low temperature heating function was canceled. Turn off and then turn on
air conditioner that will remain the low temperature heating function. After powered on, the low temperature heating mode was
default to off status.
● In the low temperature heating mode, "SLEEP" and "Low temperature heating" function cannot start at same time.When low
temperature heating mode has already started, meanwhile you press the "SLEEP
" button, the air conditioner will exit low
temperature heating mode and enter the sleep mode. Vice versa.
Note:
1. In the low temperature heating mode, the fan speed was default to Auto and non-ajusatable.
2. In the low temperature heating mode, "TURBO" and "QUIET" can't be set. If enter the low temperature heating mode, the turbo
and quiet function that started before will be canceled. As well as when exit the low temperature heating mode, it will not resume.
3. When exit from the low temperature heating mode, the speed and temperature will turn into the original condition before it started.
4. You can set up other function.
The maximum heating temperature setting
Low temperature heating function setting