___________________________________________________________________________________________________________
Rev.
7/10/15
Page 2 of 5
Skytech RCAF-LMF-V
4.
Replace the AFLMF front original faceplate that came installed on the AFLMF with the new faceplate supplied with the
RCAF-LMF-V and reinstall the (2) screws and tighten
. Note: the new faceplate has (2) large holes.
5.
Make sure to locate the RED & BLACK wires so they come out the back of the AFLMF to connect to the receiver.
Figure #1
Figure #2
WIRING INSTRUCTIONS
CONNECTING THE RECEIVER TO THE AFLMF VALVE KIT WITH THE HI/LO DC MOTOR DRIVE
1. Connect the BLACK 18 gauge stranded wire with the 1/4’ female terminal from the receiver to the BLACK wire with the 1/4” male
terminals from the HI/LO Dc motor drive.
2. Connect the RED 18 gauge stranded wire with the 1/4’ female terminal from the receiver to the RED wire with the 1/4” male
terminals from the HI/LO Dc motor drive
3. After receiver wires are connected to the valve solenoid wire make sure the receiver shield is located over the receiver and then
locate the receiver in an area that will not exceed the 130° F. This location will always be away from the AFLMF towards the front of
the firebox.
IMPORTANT NOTE:
Operation of these controls is dependent on which wire is attached to which terminal. If operation of control
does not correspond to operating buttons on transmitter, reverse wire installation at the receiver or at the control.
NOTE
: Up to 6.3 VDC of power is provided at the receiver terminal.
www.FireplaceRemoteControls.com
1.888.977.6849