___________________________________________________________________________________________________________
Rev.
7/10/15
Page 5 of 5
Skytech RCAF-LMF-V
TROUBLE SHOOTING
If you encounter problems with your fireplace system, the problem may be with the fireplace itself or it could be with the RCAF-LMF-V
remote system. Review the fireplace manufacturer's operation manual to make sure all connections are properly made. Then check
the operation of the remote in the following manner:
1. Make sure the batteries are correctly installed in the RECEIVER. One reversed battery will keep receiver from operating properly.
2. Check battery in TRANSMITTER to ensure contacts are touching (+) and (-) ends of battery. Bend metal contacts in for tighter fit.
3. Be sure RECEIVER and TRANSMITTER is within 20 to 25-feet operating range.
4. Keep RECEIVER from temperatures exceeding 120° F. Battery life shortened when ambient temperatures are above 115° F.
5. If RECEIVER is installed in tightly enclosed metal surround, the operating distance will be shortened.
SPECIFICATIONS
BATTERIES:
Transmitter 12V - (A23)
Remote Receiver 6V - 4 ea. AA 1.5 Alkaline
FCC ID No.'s: transmitter - K9L1002TX; receiver - K9L300IRX
Operating Frequency: 303.8 MHZ
Canadian ISC ID No.'s: transmitter - 2439 102 728; receiver - 2439 102 728A
FOR TECHNICAL SERVICE, CALL:
U. S. INQUIRIES
CANADIAN INQUIRIES
(888) 672-8929 or (260) 459-1703
(877) 472-3923
WEBSITE: skytechpg.com
MANUFACTURED EXCLUSIVELY FOR SKYTECH II, INC.
FCC REQUIREMENTS
NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY
UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S
AUTHORITY TO OPERATE THE EQUIPMENT.
www.FireplaceRemoteControls.com
1.888.977.6849