PROGRAMMING  SETUP 

PROGRAM STEP 1:

 

Set THERMO mode

 to your desired 

cool

 temperature (for example, 67

o

Press the 

[MODE] 

button to place the transmitter into THERM mode,

Press the 

UP 

or 

DOWN 

icons on the touchscreen to select the target temperature you

want for cooler periods of the day (for example, 67

o

).

The transmitter will send either a THERMON or THERMOFF signal to the appliance every 2 minutes, 
based on the set temperature and the ambient temperature in the room. The temperature swing 
differential will determine at what temperature the room needs to drop down to before the 
thermostat will send a THERMON signal.  For example, if the swing is 2

o

, the room will drop to 65

o

 

before the thermostat will call for heat when the THERMO mode is set to 67

o

Note: The highest set temperature is 99 ºF. 

PROGRAM STEP 2:

 

Setting the Temperature Swing Differential 

The THERMO Mode on the transmitter operates the appliance whenever the room temperature varies a certain number 
of degrees from the set temperature. This variation is called the “SWING” or TEMPERATURE DIFFERENTIAL.  The factory 
preset swing temperature is 2

o

F. To change the “Swing Setting:” 

Simultaneously press the 

[SET]

 button and the 

DOWN

 icon on the touchscreen to display the current “swing”

setting in the set temp frame. The letter “S” will display in the room temp frame on the LCD screen.
Press the 

UP

 or 

DOWN

 icon on the touchscreen to adjust the “SWING” temperature (1

o

-3

o

 F).

Press the 

[SET]

 button to store the “swing” setting.

PROGRAM STEP 3: Plan your programs

 

Example Programs: 

WEEKENDS ( S S 

)  

On the weekends,

 

I like it to be warm all day and cooler at night.   

Program 1 ON at 5:00 AM until 

OFF at Noon (12:00 PM)

 set Warm Target Temp: 72

Program 1  ON & OFF Times must be between midnight (12:00 AM) and noon (12:00 PM) 

Program 2 

ON at Noon (12:00 PM)

 until OFF at 11:00 PM set Warm Target Temp to 72

Program 2  ON & OFF Times must be between noon (12:00 PM) and midnight (12:00 AM) 
At 11:00 PM, the target temp will drop to the cool temperature set in 

PROGRAM

 

STEP 1

WEEKDAYS (M T W T F)

  

On weekdays, I like it to be warm in the morning, cooler when I am at work, warmer when I 

come home, then cooler at night.  This is the factory preset program for weekdays: 
Program 1 ON at 5:00 AM until OFF at 9:00 AM set Warm Target Temp: 72

 

At 9:00 AM, the target temp will drop to the cool temperature set in 

PROGRAM

 

STEP 1

Program 2 ON at 4:00 PM  until OFF at 10:00 PM set Warm target Temp: 72

 

At 10:00 PM, the target temp will drop to the cool temperature set in 

PROGRAM

 

STEP 1

Plan 

your

 program using this worksheet: 

Thermostat (Cool) Target Temperature:

 _____

o

 

WEEKENDS: 

Program 1:   (ON) Warmer at   __:_____   (OFF) Cooler at __:___   Warm Target Temp:  ____

Program 1 ON & OFF Times must be between midnight (12:00 AM) and noon (12:00 PM) 

Program 2:   (ON) Warmer at   __:_____   (OFF) Cooler at __:___   Warm Target Temp:  ____

Program 2 ON & OFF Times must be between noon (12:00 PM) and midnight (12:00 AM) 

WEEKDAYS: 

Program 1:   (ON) Warmer at   __:_____   (OFF) Cooler at __:___   Warm Target Temp:  ____

Program 1 ON & OFF Times must be between midnight (12:00 AM) and noon (12:00 PM) 

Program 2:   (ON) Warmer at   __:_____   (OFF) Cooler at __:___   Warm Target Temp:  ____

Program 2 ON & OFF Times must be between noon (12:00 PM) and midnight (12:00 AM) 

Содержание RC-AA-PROGR

Страница 1: ...or if the LCD screen does not illuminate when you touch it check battery position and if the batteries are fully charged TRANSMITTER BUTTONS 1 MODE Switches the appliance on thermo off 2 PROG Turns on and off the program function 3 SET Used in different functions to confirm settings 1 BATTERY ICON Battery power is low See SETUP STEP 2 2 ROOM Indicates CURRENT room temperature 3 SET Indicates desir...

Страница 2: ...ry position and that the batteries are fully charged SETUP STEP 3 Check that you are not in Child LOCK OUT mode CP This remote control includes a CHILDPROOF LOCK OUT feature that allows the user to LOCK OUT operation of the appliance from the handheld Transmitter To activate the LOCK OUT feature simultaneously press and hold the UP icon on the touchscreen and the SET button for 5 seconds The Lock ...

Страница 3: ... the receiver beeps This remote control has a COMMUNICATION SAFETY function built into its software It provides an extra margin of safety when the Transmitter is out of the normal 20 foot operating range of the receiver At all times and in all OPERATING MODES in addition to the THERMOFF or THERMON signal that is sent every 2 minutes the transmitter sends an RF signal every 15 minutes to the receiv...

Страница 4: ...ograms Example Programs WEEKENDS S S On the weekends I like it to be warm all day and cooler at night Program 1 ON at 5 00 AM until OFF at Noon 12 00 PM set Warm Target Temp 72o Program 1 ON OFF Times must be between midnight 12 00 AM and noon 12 00 PM Program 2 ON at Noon 12 00 PM until OFF at 11 00 PM set Warm Target Temp to 72o Program 2 ON OFF Times must be between noon 12 00 PM and midnight 1...

Страница 5: ...mperature will flash See Fig 3 Use the UP and DOWN icons on the touchscreen to select the P1 target temperature then press the SET button P2 ON will flash See Fig 4 Select the time you want your appliance to turn up to the P2 target temperature by pressing the UP and DOWN icons on the touchscreen then press the SET button P2 OFF will flash See Fig 5 Select the P2 OFF time for your appliance to tur...

Страница 6: ... the transmitter upon initial use if batteries are replaced or if a replacement transmitter is purchased from your dealer or the factory Refer to STEP 4 The microprocessor that controls the security code matching procedure is controlled by a timing function If you are unsuccessful in matching the security code on the first attempt wait 1 2 minutes before trying again this delay allows the micropro...

Страница 7: ... 4 Make sure the transmitter is within the 15 20 range of the receiver 5 Positioning of the receiver is important If the receiver is enclosed in a metal surround the operation of the receiver may be affected as noted below Reposition the receiver to improve operating range It is suggested that a heat shield be installed to protect the receiver from extreme heat If the receiver is enclosed in a met...

Страница 8: ......

Отзывы: