background image

REV. 11-16-18  Page 12

Round Flat Disc Fire Pits

FIRE PIT MAINTENANCE 

1.  The fire pit should be inspected and cleaned before initial use at least annually by a qualified field service person.

2.  Any component that is found faulty must be replaced with an approved component.

3.  Any tampering or modifying with the fire pit is dangerous and voids all warranties.

4.  During winter months in cold climates and various seasons operation the fire pit may be affected by weather 

     conditions.  It is recommended to use a cover/lid for your fire pit to protect it from humid/rainy weather conditions  

 

     when not in use.  Heavy rains/downpours could affect the fire pit operation if not covered; if this occurs 

     ensure you allow the fire pit time to dry out before attempting to operate.  

NOTE

: If a combustible type cover is used

     over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard.

5.  Over time stainless steel parts can discolor when heated, usually a golden or brown hue.  This discoloration is normal    

     and does not affect the performance of the appliance.

MT TROUBLE SHOOTING

Symptom

  

Remedy

 

Fire pit won’t light 

1. Bleed gas line.

 

 

 

2. Ensure all gas supply lines are turned ON.

 

 

 

3. Ensure there is not too much media overtop of burner; it can inhibit gas from flowing.

 

 

 

4. Check gas pressure.

Low flame 

 

1. Ensure the base media is at least 1 to 2-inches in diameter and top media is no more than  

 

 

                              1-inch over top of burner.

 

 

 

2. Ensure all shut-off valves and key valve is fully open.  See page 11.

 

 

 

3. Check for spider webs inside the orifice.

 

 

 

4. Check gas pressure.

Water in my fire pit 

1. Excess dust/sand material from media may be blocking the weep holes to relieve water.          

 

 

                 Remove all media and unplug weep holes.  Clean or install new media free of dust and dirt.

 

 

 

2. Ensure fire pit enclosure has proper drainage for water and proper ventilation to dry out.

 

 

 

3. Recommend to purchase a cover/lid to keep excessive water out of the fire pit.

Whistling Noises 

1. Check media to ensure it is not too tightly packed around the burner tube.

 

 

 

2. Ensure a non-whistling flex connector is being used.

SECTION 

A - MA

TCH LIGHT (MT) INST

ALLA

TION

f i r e - p a r t s . c o m

Содержание Firegear Outdoors FPB-20DBSMT-N

Страница 1: ...20 Round Flat Disc TFS system FPB 20DBSTFS P FPB 26DBSMT N 26 Round Flat Disc MT system FPB 26DBSMT P FPB 26DBSTMSI N 26 Round Flat Disc TMSI system FPB 26DBSTMSI P FPB 26DBSTFS N 26 Round Flat Disc...

Страница 2: ...nt DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicini...

Страница 3: ...erial due to rapid temperature differences When this happens the media has the potential to crack or pop outside the fireplace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of...

Страница 4: ...6DBSTFS N FPB 26DBSTFS P 1 16 26 26 1 2 18 19 69 18 FPB 29DBSMT N FPB 29DBSMT P 1 16 29 29 1 2 18 19 69 18 FPB 29DBSTMSI N FPB 29DBSTMSI P 1 16 29 29 1 2 18 19 69 18 FPB 29DBSTFS N FPB 29DBSTFS P 1 16...

Страница 5: ...C Table 3 Gas Pressures Disclaimer Btu listings are based on 7 0 WC for Natural Gas and 11 0 WC for Liquid Propane LP at the burner orifice Flex line size and proper gas pipe sizing will also affect B...

Страница 6: ...l flex gas line supplied with the fire pit IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier This appliance must be isolated from the g...

Страница 7: ...the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure Th...

Страница 8: ...REV 11 16 18 Page 8 Round Flat Disc Fire Pits Section A Match Light MT Installation fire parts com...

Страница 9: ...e products are designed for outdoor use only Not approved for any indoor use 9 This fire pit is designed to have lava rock completely covering the spur burner so that the burner is not visible Do not...

Страница 10: ...ve in place Key Valve Flange Non Combustible Wall Material Non Combustible Wall Material Key Valve Black Iron Nipple SECTION A MATCH LIGHT MT INSTALLATION ON O FF Stone Cap Flat Disc With Spur Man Mad...

Страница 11: ...onnection before each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This app...

Страница 12: ...usually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance MT TROUBLE SHOOTING Symptom Remedy Fire pit won t light 1 Bleed gas line 2 Ensure all ga...

Страница 13: ...alve U1 8D S U1 8D S Fitting Fire Pit Pan Inlet Gas Supply Expanded View of Match Throw MT Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all m...

Страница 14: ...REV 11 16 18 Page 14 Round Flat Disc Fire Pits Section B Thermocouple Manual Safety TMSI Installation fire parts com...

Страница 15: ...t National Fuel Gas Code ANSI Z223 1 NFPA54 or CSA B149 1 Natural and Propane Installation Code in Canada 6 Fire pits create high temperatures it is very important to have any combustibles at a safe d...

Страница 16: ...the ignitor probes be properly aligned over top of the burner port holes and did not move during shipping Use the Fig 16 as a guide Before lighting remove the screen cover of the ignition hood to burn...

Страница 17: ...n disconnected from its fuel supply Natural or LP gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance Fig 18...

Страница 18: ...ually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance TMSI TROUBLE SHOOTING Symptom Remedy Fire pit won t light 1 Bleed gas line 3 Ensure all ga...

Страница 19: ...r Teflon tape resistant to all gasses on all male NPT threads not flared fittings Ensure all connections are tight and check for gas leaks before and after assembly is complete Manual Gas Valve ST3 08...

Страница 20: ...REV 11 16 18 Page 20 Round Flat Disc Fire Pits Section C Thermocouple Flame Sense TFS Installation fire parts com...

Страница 21: ...11 CAUTION The fire pit enclosure MUST have a minimum ventilation of 18 square inches on each side to keep the inside of the finished enclosure dry We recommend installation of a VENT KIT 6x12 See acc...

Страница 22: ...ld be flush with the finish materials to ensure weatherproof cover lid has room clearance to open See Fig 23 3 The fire pit has 12 feet of wiring outside of the valve box underneath the burner pan One...

Страница 23: ...is important check that the ignitor probes be properly aligned overtop of the burner port holes and did not move during shipping Use the Fig 24 as a guide Before lighting remove the screen cover of th...

Страница 24: ...learned to this electronic module up to a total of three transmitters are available Contact Firegear to discuss additional transmitter options or see the accessory page of this instruction manual Lea...

Страница 25: ...s in this appliance LIGHTING INSTRUCTIONS NOTE It may take several cycles of ON OFF to purge the airflow from the gas lines The direct spark ignition will turn OFF after 15 seconds if the burner does...

Страница 26: ...ds from module are plugged into the PILOT connection on the valve body 6 Ensure green white leads from module are plugged into the MAIN connection on the valve body 7 Verify lead from igniter on elect...

Страница 27: ...ntrol module Igniter Electrode Sparks Frequently During Operation 1 The control module will generate a spark at the igniter electrode if the system is in the ON position but does not sense a flame 2 M...

Страница 28: ...couple over rainshield on page 22 Fig 23 2 Thermocouple reading should be between 10 20mV Test at the brass ground lead on gas valve and the gold lead at S terminal on the control module If no minimum...

Страница 29: ...ack Wire Flat Disc Pan Spur Burner Ignition Hood 7 8 Washer Brass Nut OAS NG Burner Orifice Coupler T 200 9898 46 Flex Conector Note Use joint compound or Teflon tape resistant to all gasses on all ma...

Страница 30: ...REV 11 16 18 Page 30 Round Flat Disc Fire Pits Replacement Parts Accessories fire parts com...

Страница 31: ...OT 10 11 12 13 Remote Off S I ADJ IPI POWER Learn AUX 17 19 AA Batteries AA Batteries AA Batteries AA Batteries 20 5 7 LOW HI OFF ON 25 4 6 O N O F F 15 14 16 22 23 24 28 29 18 30 36 37 38 21 Requires...

Страница 32: ...d Key 1 KEY PC 12 x 13 Chrome Cover Plate 1 CVR BVL2CP x 14 Thermocouple for TFS Pilot Must be ordered with item 15 1 ST3 040 1023 x 14 Thermocouple for TMSI Pilot 1 ST3 040 1025 x 15 Thermocouple Bra...

Страница 33: ...ield Replacement Kit not shown 1 TFS IGNT ASSEMBLY x 40 Thermocouple Rainshield Replacement Kit not shown 1 TMS TC ASSEMBLY x 41 Manual Spark Ignitor Module not shown 1 3042 RB x 42 23 Piezo Extension...

Страница 34: ...alves Model 01 387 OD Flare x FIP Model 01 487 OD Flare x FIP Model 01 266 OD Flare x OD Flare Model 01 288 OD Flare x OD Flare Model ADP10 OUT 10 wire ADP70 OUT 70 wire Outdoor approved 7 5VDC adapte...

Страница 35: ...ocation or failure to perform normal and routine maintenance Damage due to severe weather conditions such as hail hurricanes earthquakes tornadoes discoloration due to over heating exposure to chemica...

Страница 36: ...on to be easily read Note Mounting plate can also be installed into a paver control panel PAVER CP TMSI bracket system Using scissors carefully cutout the template and trace it on your concrete board...

Страница 37: ...REV 11 16 18 Page 37 Round Flat Disc Fire Pits NOTES fire parts com...

Страница 38: ..._____ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 Wh...

Отзывы: