background image

 

 

Remote Control Power Settings 

 

(SKY-MRCK, SKY-MRCK-TH, SKY-CON, & SKY-CON-TH) 

 
 

The electronics in this remote control system have the capability of powering two (2) different types of DC powered 
components, they are as follows. 
 
On the SKY-MRCK & SKY-MRCK-TH receivers come from the factory programmed to provide 

continuous

 DC voltage 

(4.5 VDC to 6.0 VDC) to a gas valve with a servomotor when the OFF/Low or On/Hi buttons on the transmitter are 
depressed. (This is referred to as the 1001SR Setting in the Power Setting section of the remote control section of the 
installation instructions) 
 
On the SKY-CON & SKY-CON-TH receivers come from the factory programmed to provide a 

pulse 

DC voltage (4.5 

DCV to 6.0 DCV) to a gas valve that uses a latching relay or solenoids when the OFF or On buttons on the transmitter are 
depressed. (This is referred to as the 1001P Setting in the Power Setting section of the remote control section of the 
installation instructions) 
 
If the receiver on the SKY-MRCK or SKY-MRCK-TH is set incorrectly set to the 1001P setting this will cause the 
servomotor to only operate each time the transmitter button is depressed. 

(STOP/START/STOP/START) 

 

If the receiver on the SKY-CON or SKY-CON-TH is set incorrectly set to the 1001SR setting this will cause the latching 
relay-solenoid not to operate when the transmitter button is depressed. 
 

 
POWER SETTING 
 

To change the factory “power setting”, from the 1001SR to the 1001P setting, first load the RECEIVER with 4-AA 
batteries as instructed in the REMOTE RECEIVER SECTION; that follows.  
 

1.

 

Slide the slide switch on receiver to the REMOTE position. 

 
2.

 

Push and hold in the LEARNING BUTTON on the front of the receiver.  You will hear a continuous “beep 
sound” for about three seconds. Continue to hold in the LEARN button, the “beep sound” will stop for about four 
seconds and then a second “beep sound”, of a different pitch, will be heard. The conversion from the 1001SR 
setting to1001P setting is complete. 

 

3.

 

To reprogram RECEIVER to the 1001SR setting, repeat process and receiver will reset to 1001SR setting. 

 

4.  The LEARN button is used to set the unique security code for your remote control system. The SECURITY 

CODE is reset during the “power setting” process.

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 

Rev. 8/2007 Page 1 

 

 

Содержание 1001-A Series

Страница 1: ... is not listed below you can call Skytech Systems at 1 888 672 8929 for technical support between 8 AM and 5 PM EST Monday thru Friday Remote Trouble Shooting for 1001 A Series Remotes 3002 3002P Remotes 5001 5301 Remotes RCAF LMF V Remotes SKY MRCK MRCKTH Remotes SKY CON SKY CONTH Remotes Remote Control Power Settings ...

Страница 2: ...the main gas supply is in ON Is the Pilot lit Valve knob in ON position Check and make sure rocker switch ON FIREPLACE is in REMOTE or OFF position If burner still doesn t light go to Step 4 3 Push the ON button on the transmitter you should hear a BEEP coming from the receiver and the burner should ignite If the burner doesn t ignite If no BEEP is heard push and hold LEARN button for 10 seconds o...

Страница 3: ... Is the Pilot lit Valve knob in ON position Check and make sure rocker switch ON FIREPLACE is in REMOTE or OFF position If burner still doesn t light go to step 5 3 Push the ON button on the transmitter you should hear a BEEP coming from the receiver and the burner should ignite If the burner doesn t ignite If no BEEP is heard push and hold LEARN button for 10 seconds on the face of the receiver R...

Страница 4: ...y is in ON Is the Pilot lit Valve knob in ON position Check and make sure rocker switch ON FIREPLACE is in REMOTE or OFF position If burner still doesn t light go to Step 4 3 Push the MODE button on the transmitter you should hear a BEEP coming from the receiver and the burner should ignite If the burner doesn t ignite If no BEEP is heard press and release the LEARN button on the face of the recei...

Страница 5: ...outlet block on the receiver when you depress the ON or OFF buttons you should read about 6 4 DC volts Max If the voltage is less than 4 0 volts you should replace the receiver batteries 4 Make sure that the receiver is not installed in or behind an enclosed metal chamber or door or in an area that exceeds 130 degrees F This condition can cause the RF signal to get lost and not communicate with th...

Страница 6: ... about 6 4 DC volts Max If the voltage is less then 4 0 volts you should replace the receiver batteries If the transmitter is sending a good signal the LED will have a flicker Heart Beat If the LED signal is steady there is a problem with the transmitter 4 Make sure that the receiver is not installed in or behind and enclosed metal chamber or door or in an area that exceeds 130 degrees F This cond...

Страница 7: ...ctly set to the 1001P setting this will cause the servomotor to only operate each time the transmitter button is depressed STOP START STOP START If the receiver on the SKY CON or SKY CON TH is set incorrectly set to the 1001SR setting this will cause the latching relay solenoid not to operate when the transmitter button is depressed POWER SETTING To change the factory power setting from the 1001SR...

Страница 8: ...ons you should read about 6 4 DC volts Max If the voltage is less than 4 0 volts you should replace the receiver batteries If the transmitter is sending a good signal the LED will have a flicker Heart Beat If the LED signal is steady there is a problem with the transmitter 3 Make sure that the receiver is not installed in or behind an enclosed metal chamber or door or in an area that exceeds 130 d...