background image

·

 

19

20 ·

INITIAL PARAMETER SETUP (USERS SET UP)

DEC INC

INC

DEC

INC

DEC

DEC INC

DEC INC

DEC INC

INC

DEC

DEC INC

DEC INC

INC

DEC

DEC INC

INC

DEC

When  you  start  a  charge  process,  the  integral  safety  timer  automatically  starts 
running at the same time. This is programmed to prevent overcharge the battery 
if it proves to be faulty, or if the termination circuit cannot detect the battery full. 
The value for the safety timer should be generous enough to allow a full charge 
of the battery.

This  program  sets  the  maximum  charge  capacity  that  will  be  supplied  to  the 
battery  during  charge.  If  the  delta-peak  voltage  is  not  detected  nor  the  safety 
timer  expired  by  any  reason,  this  feature  will  automatically  stop  the  process  at 
the selected capacity value.

The beep sounds at every time pressing the buttons to confirm your action. The 
beep or melody sounded at various times during operation to alert different mode 
changes. These audible sounds can be turned on or off.

This program monitors the voltage of input battery. If the voltage drops below the 
value you set the operation forcibly terminated to protect the input battery.

You can adjust the brightness of LCD screen at the charger.

LITHIUM BATTERY (LILON/LIPO/LIFE) PROGRAM

Lithium battery (LiIon/LiPo/LiFe) program

These programs are only suitable for charging and discharging Lithium batteries with a nominal voltage of 
3.3V,  3.6V  and  3.7V  per  cell.  These  batteries  need  to  adopt  different  charge  technique  that  is  termed 
constant  current  (CC)  and  a  constant  voltage  (CV)  method.  The  charge  current  varies  according  to  the 
battery capacity and performance.

4.2V

V

A

Ah

A

B

C

D

t

V/A/Ah

The  Lithium  polymer  battery  is  charged  at  a  constant 
current until it reaches the final charge voltage of 4.2 V 
per  cell  (B).  After  this  point  the  voltage  is  kept  at  a 
constant level, and the residual charge takes the form 
of  a  declining  current  curve  (C)  until  the  cut-off  point 
(D)  is  reached.    Charge  current  =  C/10.  At  this  point 
the battery can be disconnected from the charger, and 
is ready for use.

The final voltage of charge process is also very important; it should be precisely matched with the charged 
voltage  of  the  battery.  They  are  4.2V  for  LiPo,  4.1V  for  Lilo,  and  3.6V  for  LiFe.  The  charge  current  and 
nominal  voltage  as  for  cell  count  set  on  the  charge  program  must  always  be  correct  for  the  battery  to  be 
charged.

When you are willing to alter the parameter value in the program, press start/enter key to make it blink then 
change the value with Inc> or <Dec key. The value will be stored by pressing start/enter key once.

Ultimate 400W

Ultimate 400W

Содержание Ultimate 400W 20AMP

Страница 1: ...1 All specifications and figures are subject to change without notice Professional Balance Charger Discharger Professional Balance Charger Discharger SkyRC Technology Co Ltd 2011 Manufactured by SKYRC...

Страница 2: ...with battery management and integral balancer The unit is simple to use but the operation of a sophisticated automatic charger such as the does require some knowledge on the part of the user These ope...

Страница 3: ...t in company with a specialist INTRODUCTION Left View Right View Ventilation Fan DC input 12V 18V Temperature Probe Socket Positive Charger Output Universal Balancing Port Pitch 2 54mm Ventilation Fan...

Страница 4: ...arging During the process of discharging Ultimate 400W can monitor and balance each cell of the battery individually Error message will be indicated and the process will be ended automatically if the...

Страница 5: ...unattended when it is connected to its power supply If any malfunction is found Terminate THE PROCESS AT ONCE and refer to the operation manual Keep the charger well away from dust damp rain heat dir...

Страница 6: ...arge current Charging Did you select the appropriate program suitable for the type of battery you are charging Did you set up adequate current for charging or discharging Have you checked the battery...

Страница 7: ...to charge in series WARNING AND SAFETY NOTES The main purpose of discharging is to clean residual capacity of the battery or to reduce the battery voltage to a defined level The same attention should...

Страница 8: ...Continue on next page 13 14 PROGRAM FLOW CHART PROGRAM FLOW CHART Ultimate 400W Ultimate 400W...

Страница 9: ...ial to check one last time that you have set the parameters correctly If the settings are incorrect the battery may be damaged and could even burst into flames or explode To avoid short circuits betwe...

Страница 10: ...cess can be finished within the time term with the erroneous cell count This may cause the fatal result If the processor recognizes the cell count incorrectly at the beginning of charge or discharge p...

Страница 11: ...BATTERY LILON LIPO LIFE PROGRAM Lithium battery LiIon LiPo LiFe program These programs are only suitable for charging and discharging Lithium batteries with a nominal voltage of 3 3V 3 6V and 3 7V per...

Страница 12: ...g the voltage of Lithium polymer battery cells while charging In the balance mode the battery needs to have a balance lead to connect to the individual balance port of the charger And you need to conn...

Страница 13: ...h numbers are identical you can start charging by press START ENTER button If not press BATT TYPE STOP button to go back to previous screen to carefully check the number of cells of the battery pack b...

Страница 14: ...connection you can see the error message and press INC to know which cell is damaged CHARGING NICD NIMH BATTERY IN THE CHARGE MODE DEC Batt type Stop Elapsed time INC DEC Start Enter INC Charged capac...

Страница 15: ...START ENTER key for more than 3 seconds to start the program 3 seconds CHARGE DISCHARGE AND DISCHARGE CHARGE CYCLE OF NICD NIMH BATTERY Charge discharge and discharge charge cycle of NiCd NiMH battery...

Страница 16: ...Charge current Battery voltage DEC Start Enter INC Charged capacity 3 seconds Set up the charge current on the left and nominal voltage on the right Range of current is 0 1 20A the voltage should matc...

Страница 17: ...our convenience Ultimate 400W has a data storage and load program It can store ten batteries data representing the respective specifications of batteries You can call back the data when charging or di...

Страница 18: ...rious functions of protective and monitoring the system to verify functions and the state of its electronics In any case of occurring error the screen displays the cause of error that is self explanat...

Страница 19: ...symbol means that you must dispose of electrical from the General household waste when it reaches the end of its useful life Take your charger to your local waste collection point or recycling centre...

Страница 20: ...20 0 20 0 20 0 20 0 20 0 20 0 20 0 20 0 20 0 20 0 19 0 18 0 20 0 20 0 20 0 20 0 20 0 20 0 18 0 16 0 3 6 7 2 10 8 14 4 18 0 21 6 3 0 4 5 6 0 7 5 9 0 10 5 12 0 13 5 15 0 16 5 18 0 19 5 21 0 22 5 7 4 9...

Страница 21: ...ay compensation regardless of the legal argument employed is limited to the invoice value of those SkyRC products which were immediately and directly involved in the event in which the damage occurred...

Страница 22: ...1C current value of 600mA and a 3C current value of 3 x 600mA 1800mA or 1 8A The 1C current value for a 3200mAh battery would be 3200mA 3 2A We guarantee this product to be free of manufacturing and a...

Отзывы: