A  battery  pack  which  consists  of  different  types  of  cells  (including  different 
manufacturers)
A battery that is already fully charged or just slightly discharged.
Non-rechargeable batteries (Explosion hazard).
Batteries that require a different charge technique from NiCd, NiMH, LiPo or Gel cell 
(Pb, Lead acid).
A faulty or damaged battery.
A battery fitted with an integral charge circuit or a protection circuit.
Batteries installed in a device or which are electrically linked to other components.
Batteries  that  are  not  expressly  stated  by  the  manufacturer  to  be  suitable  for  the 
currents the charger delivers during the charge process.

Please bear in mind the following points before commencing charging:

Did  you  select  the  appropriate  program  suitable  for  the  type  of  battery  you  are   
charging?
Did you set up adequate current for charging or discharging?
Have you checked the battery voltage? Lithium battery packs can be wired in parallel 
and in series, i.e. a 2 cell pack can be 3.7V (in parallel) or 7.4V (in series).
Have you checked that all connections are firm and secure?
Make sure there are no intermittent contacts at any point in the circuit.

Charging 

During  charge  process,  a  specific  quantity  of  electrical  energy  is  fed  into  the  battery. 
The  charge  quantity  is  calculated  by  multiplying  charge  current  by  charge  time.  The 
maximum  permissible  charge  current  varies  depending  on  the  battery  type  or  its 
performance,  and  can  be  found  in  the  information  by  the  battery  manufacturer.  Only 
batteries  that  are  expressly  stated  to  be  capable  of  quick-charge  are  allowed  to  be 
charged at rates higher than the standard charge current.

Connect  the  battery  to  the  terminal  of  the  charger:  red  is  positive  and  black  is 
negative.  Due  to  the  difference  between  resistance  of  cable  and  connector,  the 
charger  can  not  detect  resistance  of  the  battery  pack,  the  essential  requirement 
for  the  charger  to  work  properly  is  that  the  charge  lead  should  be  of  adequate 
conductor  cross-section,  and  high  quality  connectors  which  are  normally  gold-
plated should be fitted to both ends.

Always  refer  to  the  manual  by  battery  manufacturer  about  charging  methods, 
recommended  charging  current  and  charging  time.  Especially,  the  lithium  battery 
should  be  charged  according  the  charging  instruction  provided  by  the  manufacturer 
strictly.

Never attempt to charge or discharge the following types of batteries.

Warning And Safety Notes  

07 ·

D100v

2

Содержание D100 V2

Страница 1: ...Instruction Manual Version 1 20 AC DC Dual Balance Charger Discharger Power Supply V2...

Страница 2: ...harging the battery must be placed in a well ventilated area Never leave the charger unattended when charging the battery WARNING Introduction Special Features Warning and Safety Notes Explanation of...

Страница 3: ...is a twin channel charger with two independent circuits which can charge batteries of varying chemistries LiPo LiFe Lilon LiHV NiMH NiCd Pb simultaneously Capable of operating as a power supply with t...

Страница 4: ...et 4mm Banana Plug Balance Lead Socket Temperature Sensor Port USB Port Micro USB Port for PC Link firmware upgrade Temperature Sensor Port Output Socket 4mm Banana Plug Balance Lead Socket Cooling Fa...

Страница 5: ...r s fault It can disconnect the circuit automatically and alarm once detecting any malfunction All the programs of this product were controlled through two way linkage and communication to achieve the...

Страница 6: ...ger from Charge Master SCAN TO GO A very unique feature of D100v2 is SCAN TO GO automatically charging system As the range of battery types and capacity becomes more and more each battery requires its...

Страница 7: ...essing Time Limit You can also limit the maximum process time to avoid any possible defect Battery Internal Resistance Meter The user can check battery s total internal resistance and each cell s inte...

Страница 8: ...of the battery to be charged or discharged to ensure it meets the requirements of this charger If the program is set up incorrectly the battery and charger may be damaged It can cause fire or explosi...

Страница 9: ...contacts at any point in the circuit Charging During charge process a specific quantity of electrical energy is fed into the battery The charge quantity is calculated by multiplying charge current by...

Страница 10: ...effect If they are partly used and recharged before the whole charge is accomplished they remember this and will only use that part of their capacity next time This is a memory effect It is said that...

Страница 11: ...NC CHARGE CURRENT 4 9A DEC INC DISCHG CURRENT 2 2A DISCHG VOLTAGE 3 0V CELL TVC YOUR RISK 4 20V DEC INC ENTER START ENTER START BATT PROGRAM SYSTEM SETTING ENTER START Stop Batt Type DEC INC SAVE PROG...

Страница 12: ...g to start the process press and hold the START ENTER button for 3 seconds When you are willing to stop the progress or go back to previous step screen press the BATT PROG STOP button once CH A CH B I...

Страница 13: ...ttery Connection 1 Connecting to power source There are two kinds of inputs for SKYRC D100v2 DC 11 18V and AC 100 240V 12V DC Battery DC power supply connection AC 100 240V power source connection 11...

Страница 14: ...ire aligned with the negative marking Ensure correct polarity For safety reasons the default setting for charging Lithium LiPo Lilon LiFe and LiHV battery is using balance adaptor to connect battery a...

Страница 15: ...t Take Channel A for example as following Then the channel B and DC power supply will take the rest power automatically For example if you set DC power supply as 20W and Channel A as 50W the Channel B...

Страница 16: ...be damaged and could even burst into flames or explode To avoid short circuits between the banana plugs always connect the charge leads to the charger first and only then to the battery Reverse the s...

Страница 17: ...A 11 1V 3S LiPo BALANCE 2 0A 11 1V 3S BATT PROGRAM Select Mode Select Program Start Press INC and DEC to go through all the programs and press START ENTER to enter LiPo BATT Program Battery Setting Pr...

Страница 18: ...ERY CHECK WAIT The charger is detecting the battery cell R shows the number of cells detected by the charger and S is the number of cells set by you on the previous screen If the two numbers are not i...

Страница 19: ...ty timer ON and duration of time in minutes Capacity cut off ON and value of the set capacity limit Voltage of each cell in the battery pack when the battery is connected with balance lead Internal te...

Страница 20: ...D100v2 press the INC or DEC button repeatedly until you reach the appropriate program for the battery type you wish to charge For this example we have chosen the NiMH BATT or NiCd BATT program Now pre...

Страница 21: ...p charging NiMH NiCd Discharge Mode After selecting the correct battery type use the INC or DEC button to select the DISCHARGE mode Press the START button and the amp rate value will begin flashing Us...

Страница 22: ...E AMPERAGE AND VOLTAGE SETTINGS ENTERED IN CHARGE MODE After selecting the correct battery type use the INC or DEC button to select the RE PEAK mode Press the START button and the Re peak cycle number...

Страница 23: ...e the INC or DEC button to change this setting Pressing the START button again will cause the cycle count to begin flashing Use the INC or DEC button to change this to the number of cycles you want th...

Страница 24: ...with nominal voltage ranging from 2 to 20V which are significantly different from NiMH NiCd batteries Pb batteries are suggested to charge with a low current of 0 1C and cannot be used for fast charg...

Страница 25: ...te Pb Charge 1 5A 12 0V 6P P 6 1 5A 13 56V CHG 002 22 00106 Press the START button again and the nominal battery pack voltage will begin flashing Use the INC or DEC buttons to set the voltage and the...

Страница 26: ...ight will flash red and stop working ENTER CH1 50 CH2 50W DC SUPPLY 150W To use D100v2 as a power supply the user must connect it to AC power source When the green LED on the back side turns on then t...

Страница 27: ...ss START ENTER to make it blink then change the value with INC or DEC The value will be stored by pressing START ENTER once Note All following screen are taking 6S 22 2V LiPo battery for example Enter...

Страница 28: ...ved profile 2 Battery Memory Call Out Press START ENTER for 3 seconds to start the process START ENTER 2 Seconds 26 D100v2 Please scan and watch the tutorial video about how to set battery memory and...

Страница 29: ...cal reaction will cause the temperature of the battery to rise If the temperature limit is reached the process will be terminated OFF ON 100 50000 mAh It will be operated with the default value of the...

Страница 30: ...monitors the voltage of input battery If the voltage drops below the value you set the operation forcibly terminated to protect the input battery This program is for NiMH NiCd battery only When the ch...

Страница 31: ...PROGRAM BATT METER 4 20 4 19 4 19 V 4 18 4 18 4 19 V MAIN 25 13V H4 200V L4 182V Press the START ENTER to enter the Lithium Battery Meter program The screen indicate each cell s voltage The screen in...

Страница 32: ...ocket Press the START ENTER to enter the Lithium Battery Resistance program The screen indicate each cell s resistance The screen indicate the total resistance the highest resistance and the lowest re...

Страница 33: ...ownload the SkyCHARGER App Scan with your Smartphone to download Connect the power cord to D100v2 then plug the power cord into the outlet 100 240V AC 50 60Hz Connect the batteries to the correspondin...

Страница 34: ...500mAh 24 58V A 4 65 Battery Fuel Gauge C F 50 122 LiPo 6 4 09V 4 10V 4 10V CH A CH B 89 0D0E07D5 1 15 53 Revo LiPo BAL CHARGE 6 More Back Operation Mode Battery Type Battery Cells Charge Current STAR...

Страница 35: ...HARGE Charge Current Voltage Cut Off START EDIT CANCEL 15 53 Revo CH A CH B LiPo BAL CHARGE Cells 6 Charge Curretn 5 0A Voltage 4 20V PROGRAM SYSTEM HOME Press to save the program after set the charge...

Страница 36: ...nge of battery types and capacity becomes more and more each battery requires its own dedicated charging process It is easy to set up the charger incorrectly for a specific type of battery resulting d...

Страница 37: ...er Using the App Video Tutorial 15 53 Revo SkyRC Charger BACK Please Select Channel A B Select corresponding channels How to print QR code 15 53 Revo LiPo BAL CHARGE Cells 6 Charge Curretn 5 0A Voltag...

Страница 38: ...INT TEMP TOO HI DC IN TOO LOW Input voltage less than 11V Input voltage higher than 18V DC IN TOO HIGH BATTERY WAS FULL The battery voltage is higher than the maximum voltage which the user sets when...

Страница 39: ...you are required to use a USB cable which is not included in this package The cable must be terminated on one end with A plug and the opposite end is terminated with micro B plug which can connect to...

Страница 40: ...18 4 25V cell LiIon 4 08 4 2V cell LiFe 3 58 3 7V cell LiHV 4 25 4 35V cell Balance Current 300mA cell Reading Voltage Range 0 1 26 1V Battery Types Cells LiPo LiIon LiFe LiHV 1 6cells NiMH NiCd 1 15...

Страница 41: ...mpatibility and Radio spectrum Matters ERM ElectroMagnetic Compatibility EMC standard for radio equipment and services Part 1 Common technical requirements Part 17 Specific conditions for Broadband Da...

Страница 42: ...s may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference t...

Страница 43: ...erred to as the C rating Some battery suppliers recommend charge and discharge currents based on the battery C rating A battery s 1C current is the same number as the battery s rated capacity number b...

Страница 44: ...tion regardless of the legal argument employed is limited to the invoice value of those SkyRC products which were immediately and directly involved in the event in which the damage occurred Liability...

Отзывы: