Pb Lead-Acid Battery Program
Press the START button again and the nominal battery pack
voltage will begin flashing. Use the INC or DEC button to set the
voltage and the number of cells.
Press and hold the START button for 3 seconds to start
charging.
Once charging has commenced, the charger will display the
following real-time information: battery type, charging current,
battery voltage, working mode
,
elapsed time and charged
capacity.
When charging is complete, the screen will read “FINISHED”
and the charger will emit a ringing sound.
Pb Discharge Mode:
After selecting the correct battery type, use the INC or DEC buttons to change it to the
“DISCHARGE“ mode.
Press the START button and the amp rate value will begin flashing. Use the INC or DEC
buttons to adjust the value to the desired discharge rate. Follow the instructions provided
with your battery when setting the amp rate.
Pb Charge
1.5A 12.0V(6P)
P-6 1.5A 13.56V
CHG 002:22 00106
Press the START button again and the nominal battery pack
voltage will begin flashing. Use the INC or DEC buttons to set
the voltage and the number of cells.
Press and hold the START button and discharging will begin.
Once discharging has commenced, the charger will display the
following real-time information: battery type, cell count
,
discharging
current, battery voltage, elapsed time and discharged capacity.
When discharging is complete, the screen will read “FINISHED”
and the charger will emit a ringing sound.
Additional Pb Process Information:
During the Pb battery charging/discharging process the D100v
2
can display a variety of
information. Using the INC or DEC buttons you can also view the following information:
Pb Discharge
1.5A 12.0V(6P)
P-6
1.0A
13.56V
DCH
005:10
00964
Capacity Cut-Off
ON 5000mAh
Temp Cut-off
50
C
In Power Voltage
12.56V
Safety Time
r
ON 200min
Ext. Temp ----
Int. Temp 37
C
Capacity cut-
off setting
Temperature
cut-off
Input voltage
Safety timer
setting
External*/ internal
temperature
23 ·
D100v
2