01/05/2020
45/56
E_MH_Mounting_instructions_Skylux_Climalux
Finish
Installation screwable side clip
Drill holes with a Ø of 5.5 mm in the CLSB every 500 mm, starting and ending at 200 mm from the ends. Fasten
the CLSB to the side rafter DX using ZSB screws. Fasten perpendicularly and use a slight torque to ensure the
screw head is pressed flat against the CLSB.
Cut the CLLX/CLSL profile obliquely in accordance with the roof slope (x) at the wall side. To determine the length
of the CLLX/CLSL profile, measure the distance to the stop profile. Position the CLLX/CLSL profile at the outside
against the rafter and press manually or use a rubber hammer with a plank. If you work with VRIJSTAAND or
against the wall, it is necessary to fasten the CLLX/CLSL profile every metre laterally against the rafter (with ZSG)
or against the wall.
1000
250
α
ZSG
ZSG
CLLX/CLSL
500
200
Содержание Climalux
Страница 1: ...CANOPY Climalux Climalux Horizon Mounting instructions EN Art N 36179...
Страница 16: ...E_MH_Mounting_instructions_Skylux_Climalux 01 05 2020 16 56 Climalux Installation tips...
Страница 48: ...E_MH_Mounting_instructions_Skylux_Climalux 01 05 2020 48 56 Finish Click the cover on the post PCLX PCLXLX...