208932AEA
SJ85AJ
58
Section 5 – Operation
Start Operation
5.1 Start Operation
5.1-1 To Activate Base Control Console
WARNING
Ensure that you maintain three points of contact
when using the ladder to mount/dismount platform.
1.
Enter platform and close gate/drop bar.
2.
On platform control console, pull out
emergency stop button.
3.
Dismount from platform.
4.
In engine compartment, turn main power
disconnect switch to
on position.
5.
On base control console, turn off/base/platform
key switch to
base position.
6.
Pull out
emergency stop button.
7.
Select
start position from start/function
enable/emergency power switch until engine
starts.
WARNING
DO NOT over crank the starter. If engine fails to
start after multiple attempts, contact qualified/
competent repair personnel.
5.1-2 To Rotate Platform Using Base
Control Console
1.
Activate function enable
by selecting and
holding start/function enable/emergency power
switch to function enable position.
2.
Push platform rotation switch to either
left or
right position. Release switch to stop.
5.1-3 To Rotate Turret Using Base Control
Console
WARNING
When rotating the turret, ensure that there are no
personnel or obstructions in the path of rotation,
including blind spots.
1.
Activate function enable
by selecting and
holding start/function enable/emergency power
switch to function enable position.
2.
Push turret rotation switch to either
clockwise or
counterclockwise position.
Release switch to stop.
NOTE
Turret can be rotated continuously 360 degrees.
5.1-4 To Move Jib Up and Down Using
Base Control Console
1.
Activate function enable
by selecting and
holding start/function enable/emergency power
switch to function enable position.
2.
Push jib up/down switch to either
up or
down position. Release switch to stop.
5.1-5 To Move Riser Up and Down Using
Base Control Console
1.
Activate and hold function enable switch
by
pushing it to the right.
2.
Push riser up/down switch to either
up or
down position. Release switch to stop.
5.1-6 To Raise or Lower Main Boom
Using Base Control Console
NOTE
Maximum platform capacity varies with boom
position. Indicator lights on the base and platform
control consoles indicate whether platform is in
the “high” or “low” capacity zone.
1.
Activate function enable
by selecting and
holding start/function enable/emergency power
switch to function enable position.
2.
Push main boom raise/lower switch to either
raise or
lower position. Release
switch to stop.
Содержание SJ85AJ
Страница 1: ...OPERATING MANUAL SJ85AJ ARTICULATING BOOMS 208932AEA November 2018 AS...
Страница 4: ...208932AEA SJ85AJ 4 Notes...
Страница 18: ...208932AEA SJ85AJ 18 Notes...
Страница 62: ...208932AEA SJ85AJ 62 Notes...
Страница 68: ...208932AEA SJ85AJ 68 Notes...
Страница 69: ...SJ85AJ 208932AEA 69 Section 7 Technical Diagrams Specifications...
Страница 78: ...208932AEA SJ85AJ 78 Notes...
Страница 102: ...208932AEA SJ85AJ 102 Notes...
Страница 104: ...208932AEA SJ85AJ 104 Notes...
Страница 105: ......
Страница 106: ...www skyjack com...