61
SJ30 AJE SJ30 ARJE
213213AAA
Start Operation
Section 5 – Operation
5.1-21 Sounding horn
1.
Press horn pushbutton to sound horn. Release
pushbutton to stop sounding horn.
5.1-22 Rotating turret using platform
control console
WARNING
When rotating the turret, ensure that there are no
personnel or obstructions in the path of rotation,
including blind spots.
1.
Depress and hold footswitch.
2.
Push and hold boom/turret controller
in this direction to rotate clockwise or
counterclockwise.
3.
Release controller handle to stop.
5.1-23 Operating with emergency power
switch at platform control console
This is a momentary-type switch. This switch allows
all functions except drive functions to operate in the
event of an emergency or an electrical system failure.
Refer to
Section 6.1
for the emergency lowering
procedure.
NOTE
The emergency power unit has two-minute duty
cycle.
CAUTION
Do not use emergency power unit continuously for
more than two minutes.
5.1-24 Shutdown procedure
1.
Select a reasonably well-protected parking
location with a firm, level surface, clear of
obstructions and traffic.
2.
Completely retract boom and lower platform.
3.
Push in emergency stop button on platform
control console and on base control console.
4.
Turn base/off/platform key switch to off position.
Remove key.
5.
On either the left or right side of the MEWP,
disconnect and lock out main power connector.
6.
If necessary, cover platform control console to
protect warning labels and operating controls
from hostile environments.
5.1-25 Inverter (if equipped)
1.
On both the left and right sides of the MEWP,
plug in main power connectors.
2.
Make sure on/off switch of the inverter is on
position.
3.
Inverter state is indicated by the LEDs on
the face of the inverter. A glowing green LED
indicates normal operation. If a fault occurs, the
status LEDs will indicate the area responsible.
To
order
go
to
Discount-Equipment.com