Optional Equipment and Attachments
Section 3 – Familiarization
Using keypad:
NOTE
The keypad is touch sensitive. An audible beep
will provide feedback that input was successfully
received.
1.
Enter PIN code.
2.
Press green checkmark to confirm.
▪
Result:
Green light indicates authorized ID.
Begin operation.
NOTE
If an incorrect button is pressed while inputting
the PIN code, press the Cancel key to start over.
Using smart ID card:
1.
Place card in front of reader.
2.
A beep signal indicates card has been read.
▪
Result:
Green light indicates authorized ID.
Begin operation.
NOTE
The controls must become active within the time
set by the machine owner for access control
operation. DO NOT use keypad and tap card
simultaneously.
IMPORTANT
The access control unit will time out and become
inactive if the operator has not completed the
activation of the controls. The length of time before
the unit times out is set by the machine owner.
If the access control unit times out, the operator
needs to enter the unique PIN code or tap the
smart ID card again. If access control activation
fails, contact the machine owner.
IMPORTANT
The access control unit will become inactive if
the operator performs any of the following power
disconnections, and the predetermined amount of
time set by the machine owner has elapsed:
▪
turns the main power disconnect to the OFF
position, pushes in the base emergency stop
button or turns the key switch to the OFF
position.
Skyjack DOES NOT manage the time out settings
of the access control unit. Contact machine owner
if time out settings need to be modified.
IMPORTANT
To reactivate the access control unit, the operator
needs to enter the unique PIN code or tap the
smart ID card again. To maintain access, the
operator must ensure that the main power
disconnect is in the ON position, the base
emergency stop is pulled out, and that the key
switch is in platform or base mode within the
time set by the machine owner for access control
functionality.
Function tests
Perform the function tests as described in
Section 4.3
.
When performing the function tests, confirm that
the access control unit is active by verifying that the
green light on the keypad is ON. When performing
main power disconnect, base emergency stop, and
off/platform/base switch function tests, the operation
must be performed within the time set by the machine
owner for access control operation.