Mid Size & Full Size RT’s
Engine Powered
February 2008
SKYJACK, Page 41
Start Operation
Section 2 - Operation
2.10-2 To Raise or Lower Platform Using Base
Control Console
wARNiNG
Be aware of overhead obstructions or
other possible hazards around the aerial
platform when lifting.
wARNiNG
Do not lower the platform unless the
area below is clear of personnel and
obstructions.
Activate base control console (refer to
1.
On the base control console at the hydraulic/
2.
electrical compartment, push in platform raise
pushbutton to “ ” raise the platform or platform
lower pushbutton to “
” lower the platform.
Release switch to stop.
2.10-3 To Activate Platform Control Console
1.
Turn emergency main power disconnect switch
to on position.
2.
For dual fuel engine, select fuel supply by moving
fuel switch to either “
” gasoline or “
” liquid
propane gas position.
wARNiNG
Ensure that you maintain three points of
contact when using the ladder to mount/
dismount platform.
3.
Use the ladder of aerial platform to access
platform.
4.
Close the gate.
5.
On platform control console, pull out “
”
emergency stop button.
6.
Insert key into off/lift/drive key switch and select
“
” lift position.
7.
Select low/high throttle switch to “
” low
throttle position.
CAUTiON
Do not start the engine in the high throttle
position.
8.
If diesel engine (if equipped) is cold,
depress and hold glow plug pushbutton for
15 to 20 seconds.
9.
Depress and hold “
” engine start pushbutton
until engine starts, then release. Do not overcrank
starter.
Содержание 7127