Length (bytes): 1
Default value: 100%
The values for the modulation depths are in steps of 10, ranging from 10% to 100%.
The values are the hex equivalent of the corresponding modulation depth.
Table 13-4: Common Modulation Depth Values
Modulation Depth (%)
Hex Equivalent
30
0x1E
80
0x50
90
0x5A
100
0x64
The modulation depth is calculated by the reader using the equation:
(V
MAX
–
V
MIN
)/V
MAX
where V
MAX
is the RF voltage when transmit power is maximum and V
MIN
is the RF
voltage when the transmit power is minimum. (For 100% modulation depth, V
MIN
equals zero.)
See the manufacturer’s tag data sheet for the modulation depth supported for the tags in your
application.
Read/write
13.3.20
Regulatory Mode
Enables pulse shaping, listen before talk, and timing modifications for regions with special regulatory
requirements, such as Europe.
Parameter address: 0x0037
Length (bytes): 1
Default value 0x00 (no pulse shaping)
Read/write
Table 13-5: Regulatory Mode Values
Mode
Hex Value
No pulse shaping
—
Australia/New Zealand, Hong Kong, North America, Singapore,
Taiwan
0x00
ETSI/Europe
0x01
Not used
0x02
Not used
0x03
Korea
0x04