System Parameters
13.1
System Parameter Summary
System parameters let you configure reader settings to customize the reader for your environment. You
can temporarily alter parameters in memory or change the default values that are stored on the
SkyeModule Nova
’s
non-volatile memory. The following table summarizes the parameters. (See System
Parameter Detail in section 13.3 for detailed information about each parameter)
Parameter Name
Address
(hex)
Num.
Blocks
(hex)
Read
/Writ
e
Default Value
Serial Number
0x0000
0x0004
R
0x00000000
Firmware Version
0x0001
0x0004
R
0xXXXXXXXX (depending on release)
Hardware Version
0x0002
0x0004
R
0xXXXXXXXX (depending on release)
Product Code
0x0003
0x0002
R
0x0010
Reader ID
0x0004
0x0004
R/W
0xFFFFFFFF
Reader Name
0x0005
0x0032
R/W
SkyeModule Nova (in ASCII Format)
Host Interface Type
0x0006
0x0001
R/W
0x01 (TTL)
Interface Baud Rate
0x0007
0x0001
R/W
0x02 (38400)
User Port Direction
0x0008
0x0001
R/W
0x00
User Port Value
0x0009
0x0001
R/W
0x0F
MUX Control
0x000A
0x0001
R/W
0x00
Operating Mode
0x000C
0x0001
W
N/A
Tag Command Retries
0x0011
0x0001
R/W
0x03
Power Level
0x0012
0x0001
R/W
0xDC (27 dBm)
Current Frequency
0x0004
0x0004
R/W
0x3689CAC0 (915 MHz)
Start Frequency
0x0031
0x0004
R/W
0x35C80160 (902.3 MHz)
Stop Frequency
0x0032
0x0004
R/W
0x374B9420 (927.7 MHz)
Hop Channel Spacing
0x0034
0x0004
R/W
0x00030D40 (200 KHz)
Frequency Hopping
Sequence
0x0035
0x0001
R/W
0x01 (pseudo-random)
Modulation Depth
0x0036
0x0001
R/W
0x64 (100%)
Regulatory Mode
0x0037
0x0001
R/W
0x00
Table 13-1: SkyeModule Nova System Parameters