Chapter 2
Skybox Appliance specifications
Skybox version 11.6.100
8
PROPERTY
LIMITS
Acoustic noise
Sound pressure: 55 dBA (rack mount) in an idle state at typical office ambient
temperature. (23 +/- 2 degrees C)
Sound power: 7.0 dBA in operating conditions at typical office ambient
temperature. (23 +/- 2 degrees C)
Shock
l
Operating: Half sine, 2 g peak, 11 msec
l
Unpackaged: Trapezoidal, 25 g, velocity change 136 inches/second (
≧
40
lb to <80 lb)
l
Non-palletized free fall height: 24 inches (
≧
40 lb to <80 lb)
Vibration,
unpackaged
5 Hz to 500 Hz, 2.20 g RMS random
ESD
+/-12 KV except I/O port +/- 8 KV per Intel
®
Environmental test specification
System cooling
requirement
2027.7 BTU/hour
EMI operating
Required to meet EMI emission requirements, tested as part of system
MTBF estimates for Skybox Appliance
The estimated mean time between failures (MTBF) and Failures in Time (FIT) for Skybox
Appliance 6000 are listed in the following table.
COMPONENT
MTBF (HOURS)
ESTIMATED FIT
Backplane board
935189
1069
PCI Riser Card
7303481
137
Front Panel board
8272282
121
Intel
®
Server Board S2600GZ
196253
5095
750W redundant power supplies (1+1)
806081
1241
Dedicated NIC module
2869529
348
Cooling fans
83131
12029
Total FIT rate
20178
System MTBF hrs @ 40°C
49560
System MTBF hrs @ 35°C
63214
System MTBF hrs @ 25°C
82325
Note: The estimates listed here are for Appliance in 35°C ambient air with a rise of up to 10°C
at the Server Board.
Front panel
Skybox Appliance 6000 front panel includes 2 USB connectors, a power button, and LEDs.