Chapter 2
Skybox Appliance specifications
Skybox version 11.7.100
10
LED
COLOR /
STATE
DESCRIPTION
System Status
Green / on
System ready/no alarm
Green /
blinking
System ready but degraded: Redundancy lost (for example, a power
supply or fan failure); non-critical temperature or voltage threshold
reached; battery failure; or predictive power supply failure.
Amber /
on
Critical Alarm: Critical power modules failure, critical fans failure,
voltage (power supply), critical temperature and voltage
Amber /
blinking
Non-Critical Alarm: Redundant fan failure, redundant power module
failure, non-critical temperature, and voltage
Off
Power off: System unplugged
Power on: System powered off and in standby, no prior degraded/non-
critical/critical state
Back panel connectors
Skybox Appliance 7000 back panel includes the connectors shown in the following figure.
By default:
l
eno1 is enabled and configured as DHCP
l
eno2 is enabled and configured as static with the IP address: 192.168.1.1 /24
You can change these values.
File system partitions
By default, the Skybox Appliance file system is partitioned as follows:
l
/tmp partition – 5%
l
/ (root) partition – 10%
l
/var partition – 30%
l
Swap partition: The swap size is set to half the total RAM but no more than 8% of total
storage
l