User Servicing Instructions
Maintenance Checklist:
1.
Ensure all mounting bolts are present and torqued to 90 ft-lb (122 N-m) using a calibrated torque
wrench.
2.
Ensure all bolts securing airfoils to the struts are present and torqued to 29 ft-lb (39 N-m) using a
calibrated torque wrench.
3.
Inspect motor terminations inside junction box and ensure their tightness.
4.
Check all connections of the fan controller and ensure their tightness.
5.
Ensure airfoils are secured to one another by boomerang brackets.
6.
Ensure screws securing wingtip fences to airfoils are tight.
7.
Check to see if gear reducer is leaking, if so please contact customer service at 1-586-806-5107.
8.
Check for the presence of the safety cable and wire rope clips. The cable should be wrapped
around the I-beam or angle irons, leaving as little slack as possible. The wire rope clips should be
securely fastened on the top side of the I-beam or angle irons.
9. Administer proper cleaning techniques such as dusting airfoils, motor, reducer and chassis. If
desired, used a water based cleaner to polish airfoils.
Maintenance Log:
Date:
Maintenance Performed
Replacement Parts Required