31
Support Hotline: +49 (0) 2661 98088-112
Support E-Mail: [email protected]
Version No. 1.0
Document No. 97013700
SKS-Kinkel Elektronik GmbH
300113 TK Adapter V2
EN
2.4
Storage and transport
Transport only on original packaging, store in a dry and cool place.
2.5
Care instructions
Just clean the device unit with a soft cloth, moistened with a mild soap solution. Dry cleaning, aggressive detergents
and abrasives may damage the surface.
2.6
Modification
A modification (alteration or conversion) of the TK Adapter V2 is not allowed
2.7
Safety
Electrical shock hazard to persons. Danger of burns, damage to device and malfunctions.
VDE 0100 and VDE 0800 guidelines must be complied during installation. (Germany)
Counter measures:
3
Before beginning any work, deactivate and disconnect all energized electrical wires.
3
Secure the switched off/disconnected lines against erroneous reconnection.
3
Use a measuring device to make sure that the wires are de-energized.
3
Cover up any adjacent, energized or conducting components.
3
All work and all electrical connections must comply with the national provisions for the country in question and
must be performed by appropriately trained personnel.
Mounting, installation, reparation and initial setup must be carried out by qualified elec
-
tricians only! When working on systems with 230 V alternating voltage the safety require-
ments of DIN VDE 0100 must be complied with.
The SKS planning guide (can be downloaded from www.sks-kinkel.de) must be followed during installation!
3 Signalling
LED
Function
Signal
Meaning
LED 1
green
Active/Power
None
No electrical voltage
Permanently lighted
Powered
1 Hz flashing (= 1 x per second)
No attendee programmed
LED 2
orange
Active door call
None
No active door call
Permanently lighted
Active door call
LED 3
orange
Mode
None
Normal operation
1 Hz flashing (= 1 x per second)
Programming mode
Note
: An active door call is interrupted when
programming mode is activated!
2 Hz flashing (= 2 x per second)
Deleting
4 Hz flashing (= 4 x per second) Deleting finished
4 Hz flashing (= 4 x per second)
Time out of DIP-switch 3